CooperSurgical
Mityvac 10022
110022 • Mityvac® Reusable Obstetrical Vacuum PumpInstructions for Use (English)CAUTION • U.S. Federal law restricts this device to sale by or on the order of a physician. • Vacuum gauges can be rendered inaccurate during shipment despite care taken in packaging. Gauge calibration must be che …
Mityvac 10022 Medical Equipment, 20
-
Dräger
Babylog VN500
D-12377-2016Disassembly/Assembly MufflerOpen the flap by lifting the lower edge upwards.Close the flap.Pull the muffler as far it will go to the left.Push the muffler to the right into the socket.Remove the expiratory valve from the fitting.Turn the locking ring as far as possible to the left.Remove and empty the …
Babylog VN500 Medical Equipment, 4
-
Hollywog
WiTouch Pro
Quick Start GuideSmartphone not required for operationFor SETUP &PAIRING INSTRUCTIONSScan QR code with camera on smartphoneor visit hollywog.com/setupApp is ONLY compatible with iOS 9.0 & above OR ANDROID 4.4 & above. IMPORTANT! Refer to the user manual for all Indications, Contraindications, Warnin …
WiTouch Pro Fitness Equipment, 2
-
Otto Bock
1C40 C-Walk
1C40 C-WalkGebrauchsanweisung ………………………………………………………. 2Instructions for use ………………………………………………………….. 9Instructions d’utilisation ……………………………………………………. 16Istruzioni per l’uso ………….. …
1C40 C-Walk Medical Equipment, 192
Recommended Documentation:
Table of Contents for Physiomed IONOSON-Basic:
-
2.2 Data Selector <2> The Data Selector <2> is used to select the therapy parameters and to operate the instrument by means of the cursor. After switching on the in- strument, the cursor is located at the current mode G of the Display <1>. You can move the cursor to the other menu items by turning the selector to the right or left. To select a menu, simply press the selector. To select a parameter, move the cursor to the respect
-
In case of a monitoring note, first perform a self-test once or several times (refer to Function Check on page 39), and check if the problem still occurs afterwards. Important Inform your service partner if the monitoring note does not disappear even after several self tests! Never perform a treatment when the proper function of the instrument is not assured! List
-
Parameters for Current Mode GMC Intensity display in microampere (1,000 µA = 1 mA) Polarity switch to switch the polarity of the two electrodes; the sign in the in- tensity display changes accordingly. Switching from galvanic current to medium-frequency interrupted direct current. NOTICE The maximum intensity of current mode GMC is so small that it is hardly perceptible. Its en- ergy is not sufficient to light Patient Current Indicator <5> and Output Indicator <6>. The diodes therefore remain dark. 3.3.3 (DF) Diadynamic Current Diphasé
-
4.1.2 Economy Mode In the battery operation mode, the instrument automatically switches over to the economy mode in the start menu to save power. The Display <1> is no longer illuminated. Turning the Data Selector <2> will re-activate the illumination. 4.2 Start-up of the Instrument Before you can perform the first treatment with the IONOSON-Basic, you have to start the instrument up accordingly. How to Start up the Instrument (1) Make sure that the instrument is switched off (the sw
-
Appendix C Supplementary Documents . . . . . . . . . . . . . . . . . . . . . . . . 74 C.1 Manufacturer’s Recommendations . . . . . . . . . . . . . . . . . . . . . . . 74 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Table of Contents PHYSIOMED ELEKTROMEDIZIN AG iv IONOSON-Basic
-
Chapter 7 Simultaneous Therapy Simultaneous therapy means the treatment with ultrasound and stimulation current at the same time. The ultrasonic transducer is one pole of the stimulation current circuit, a plate electrode the other one. It is advisable to use a plate electrode of minimum size EF50 as neutral electrode. The neutral electrode is plugged into the socket No.1 (anode of channel I) of the patient lead (refer to Patient Lead: Mode of At- tachment on page 9). Make sure that there is enough space between the plate electrode and the transducer. If
-
Type Diameter of the Electrode (cm) Effective Area (cm2) Maximum Intensity for Currents with High Galvanic Component (mA) 0 3.0 7 0.7 1 6.0 20 2 2 9.0 40 4 5.4 Preparations and Attaching the Electrodes To prepare the electrodes, proceed as follows: (1) Prior to attaching the electrodes, make sure that the intensity in both channels is turned down to zero. (2) Plug the patient lead into the Patient Lead Connector <9>. (3) Plug the plate electrodes or junction lead for other types of electrodes into the corresponding con- nectors of
-
<3> or Intensity Control Channel 2 <4>), until the muscle contraction is sufficient. The therapy time elapses. CAUTION Make sure you do not touch the electrodes when the current is turned up! When using the manual release key, release a pulse each time you turn up the intensity! During a pulse pause only turn the intensity slightly to avoid unpleasant muscle reac- tions. (11) Signs of fatigue should make you stop the treatment (the
-
Chapter 5 Therapy with Stimulation Current In this chapter, you will find general information on the therapy with stimulation current and notes to ap- ply electrodes. Furthermore, the properties and operating steps of different types of treatment with IONO- SON-Basic are described. Important Always switch on the instrument BEFORE you attach electrodes to the patient! Only switch off the instrument AFTER you have removed the electrodes from the patient! 5.1 General Information With the IONOSON-Basic, you have the following options to
-
(9) With the Data Selector <2> first click on the R symbol, rotate to the left until one of the manual control symbols appears and press to confirm. The symbols have the following meaning: • : The duration of increase is determined by pressing the manual release key, the pause by releasing the manual release key. • : Pressing the key triggers a single pulse of the preset increase duration T. (10) Set the therapy time. (11) Slowly turn up the intensity with the
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of Physiomed IONOSON-Basic device using right now.
- Описание
Портативный комбинированный аппарат с большим выбором токов низкой и средней частоты и ультразвуком 1 и 3 МГц
Стимуляционные токи:
- 2 независимых канала с возможностью выбора индивидуальных частот
- 2 независимых таймера
- Автоматическое отключение токов (независимо для обоих каналов)
Токи средней частоты:
- IFM (интерференциальная модуляция)
- AMF (биполярный ток средней частоты)
- KOTS (Русская стимуляция)
Токи низкой частоты:
- G (гальванический ток)
- GMC (гальванический микроток)
- DF, MF, CP, LP (диадинамические токи)
- UR (Траберт)
- HV
- TENS
- MENS (нервная стимуляция микротоком)
- IG 30
- IG 50
- FM
- STOCH
- FaS (ток Фарадея)
- T/R (экспоненциальный ток)
Ультразвук:
- Две частоты (1 и 3 МГц)
- Постоянный и пульсирующий режим (4 цикла)
- Оптическая и акустическая сигнализация
- Эргономичный, водонепроницаемый излучатель с контактной поверхностью из биосовместимого титанового сплава обладает высокой безопасностью для ультразвукового излучения и не вызывает аллергических реакций
- LCD (голубой) для лучшей видимости
- Запатентованное ФИЗИОМЕД управление одной клавишей для легкого использования
- Большой список показаний для процедур в алфавитном порядке с автоматическим выбором требуемой дозы излучения, графическим отображением области воздействия
- Память из 25 изменяемых индивидуальных программ, которые наиболее часто используются
- Поппури (последовательность токов)
- Одновременная терапия
- Твердый металлический кейс
- Защитная ручка
- Аппарат работает от сети (*либо от батарей)
Download Operating instructions manual of Physiomed IONOSON-Basic Medical Equipment for Free or View it Online on All-Guides.com.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
01750 GB
OPERATING INSTRUCTIONS
IONOSON—Basic
MAINS— OPERATED MODEL
BATTERY— OPERATED MODEL
Download or browse on-line these Operating Instructions Manual for Physiomed IONOSON-Basic Medical Equipment.
Summary of Contents:
[Page 1] Physiomed IONOSON-Basic 01750 GB OPERATING INSTRUCTIONS IONOSON-Basic MAINS- OPERATED MODEL BATTERY- OPERATED MODEL |
[Page 2] Physiomed IONOSON-Basic Legal Notice Distribution, reproduction and translation of the software and its documentation (or excerpts thereof) are prohibited without the prior written consent of PHYSIOMED ELEKTROMEDIZIN AG. PHYSIOMED ELEKTROMEDIZIN AG reserves the right to cha… |
[Page 3] Physiomed IONOSON-Basic Table of Contents Chapter 1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Conventions Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Instrument Symbols . . . . . . . . . . . . . . … |
[Page 4] Physiomed IONOSON-Basic 3.3.6 (LP) Diadynamic Current Modulé en Longues Périodes . . . . . . . . . . . . . 19 3.3.7 (UR) Ultra Stimulation Current. . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.8 (HV) High-Voltage Current . . . . . . . . . . . . . . . . . . . …. |
[Page 5] Physiomed IONOSON-Basic 5.5.4 Muscle Stimulation Using Low-Frequency Currents . . . . . . . . . . . . . . . 47 5.6 Therapy with Medium Frequency Current Modes. . . . . . . . . . . . . . . . 50 5.6.1 Treatment with IFM Current. . . . . . . . . . . . . . . . . . . . . . . . …. |
[Page 6] Physiomed IONOSON-Basic Appendix C Supplementary Documents . . . . . . . . . . . . . . . . . . . . . . . . 74 C.1 Manufacturer’s Recommendations . . . . . . . . . . . . . . . . . . . . . . . 74 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … |
[Page 7] Physiomed IONOSON-Basic Chapter 1 Introduction With IONOSON-Basic you have acquired a high-quality and extremely versatile combination therapy instru- ment. The instrument will only show its true potential, however, if you are well informed about its func- tions. For this r… |
[Page 8] Physiomed IONOSON-Basic 1.3 Instrument Overview Legend 1 Indicator 7 Mains Module 2 Data Selector 8 Power Switch 3 Intensity Control Channel 1 9 Patient Lead Connector 4 Intensity Control Channel 2 10 Ultrasound Lead Connector 5 Patient Current Indicator 11 Manual Release K… |
[Page 9] Physiomed IONOSON-Basic 1.4 General Notes IONOSON-Basic may only be operated in dry rooms designed for medical purposes, in accordance with DIN VDE 0100-710, User Class 1. These are rooms with patient beds, physical therapy rooms and practice rooms. It complies with the tec… |
[Page 10] Physiomed IONOSON-Basic The function of IONOSON-Basic are controlled by a microprocessor. Essential components are permanently controlled by the processor and thus faulty operation is prevented. After switching on, all instrument func- tions are checked during an automatic … |
[Page 11] Physiomed IONOSON-Basic • Conditions following radiothorium treatments, X-ray therapy • Conditions following laminectomy • Skin lesions (infections, inflammatory processes, naevi) • Tumescences at all stages (pre-/postoperative) • Blood coagulation diseases • In… |
[Page 12] Physiomed IONOSON-Basic Chapter 2 Controls and Indicators The design of IONOSON-Basic allows for easy operation, in combination with a variety of functions. Be- cause of its small size, the instrument is very easy to transport. It has been designed for operation both in- si… |
[Page 13] Physiomed IONOSON-Basic 2.2 Data Selector <2> The Data Selector <2> is used to select the therapy parameters and to operate the instrument by means of the cursor. After switching on the in- strument, the cursor is located at the current mode G of the Display <… |
[Page 14] Physiomed IONOSON-Basic 2.4 Patient Current Indicator <5> The diode at the left side of the symbol belongs to channel I, the diode at the right to channel II. The flashing of the indicators depends on the resistance in the two channels. In most cases the diodes start … |
[Page 15] Physiomed IONOSON-Basic 2.7 Power Switch <8> If you look at the instrument from the front, the Power Switch <8> is on its left side. By means of this switch, you can switch the instrument on and off. After switching on, a selftest is automatically carried out by… |
[Page 16] Physiomed IONOSON-Basic Replacing the ultrasonic transducer during treatment will not affect the selected mode of treatment. The dose, however, will automatically be turned down to zero and has to be increased again when continuing the treatment. Automatic Coupling Confirma… |
[Page 17] Physiomed IONOSON-Basic Chapter 3 Overview of Current Modes NOTICE All current modes of the instrument are emitted in the constant current mode unless other- wise specified (refer to Constant Current Operation on page 40). Only in simultaneous treat- ment (refer to Simultan… |
[Page 18] Physiomed IONOSON-Basic • (FM) Frequency-Modulated Current on page 27 • (STOCH) Stochastic Current on page 29 • (T/R) Pulses with Adjustable Parameters on page 32 • (IFM) Modulated Interference Current on page 33 • (KOTS) Medium-Frequency Muscle Training on page 3… |
[Page 19] Physiomed IONOSON-Basic Selection window for channel I (3) With the Data Selector <2>, click first on the symbol R, set the pulse pause (1- 60 s) by turning and confirm by pressing. (4) Now use the Data Selector <2> to click on the symbol T, set the pulse durati… |
[Page 20] Physiomed IONOSON-Basic • : Pressing the key triggers a single pulse of the preset increase duration T. (4) Now use the Data Selector <2> to click on the symbol to return to the start menu. The manual release key symbol is now displayed next to the pulse symbol . Im… |
[Page 21] Physiomed IONOSON-Basic Selection window for channel II (7) First use the Data Selector <2> to click on the R symbol, turn to the left until the desired symbol (simultaneous or alternating stimulation) appears and press to confirm. (8) Now use the Data Selector <2&… |
[Page 22] Physiomed IONOSON-Basic Current Mode G: Direct Current Current Mode G: Medium-Frequency Interrupted Direct Current Parameters for Current Mode G Polarity switch to switch the polarity of the two electrodes; the sign in the intensity dis- play changes accordingly. Switching … |
[Page 23] Physiomed IONOSON-Basic Parameters for Current Mode GMC Intensity display in microampere (1,000 µA = 1 mA) Polarity switch to switch the polarity of the two electrodes; the sign in the in- tensity display changes accordingly. Switching from galvanic current to medium-frequ… |
[Page 24] Physiomed IONOSON-Basic Simulation fre- quency 100 Hz Pulse time 10 ms Release time 0 ms 3.3.4 (MF) Diadynamic Current Monophasé Fixe Definition Diadynamic current monophasé fixe acc. to Bernard Application • Pain treatment Menu for Current Mode MF Current Mode MF Param… |
[Page 25] Physiomed IONOSON-Basic 3.3.5 (CP) Diadynamic Current Modulé en Courtes Périodes Definition Diadynamic current modulé en courtes périodes according to Bernard Application • Pain treatment • Resorption enhancement Menu for Current Mode CP Current Mode CP Parameters f… |
[Page 26] Physiomed IONOSON-Basic Menu for Current Mode LP Current Mode LP Parameters for Current Mode LP Polarity switch to switch the polarity of the two electrodes; the sign in the intensity dis- play changes accordingly. Pulse shape Sinusoidal half-waves; MF basic current with se… |
[Page 27] Physiomed IONOSON-Basic Menu for Current Mode UR Current Mode UR: Monophase Current Mode UR: Biphase Parameters for Current Mode UR Polarity switch to switch the polarity of the two electrodes; the sign in the intensity dis- play changes accordingly. Switching from monophas… |
[Page 28] Physiomed IONOSON-Basic Menu for Current Mode HV Current Mode HV: monophase Current Mode HV: biphase Parameters for Current Mode HV Polarity switch to switch the polarity of the two electrodes (the sign in the intensity dis- play changes accordingly); can be adjusted separa… |
[Page 29] Physiomed IONOSON-Basic (4) Press the Data Selector <2>. The arrow symbol starts flashing. (5) Press the Data Selector <2> and adjust the desired frequency (the desired frequency is displayed next to the f symbol) and press it for confirmation. NOTICE With the b… |
[Page 30] Physiomed IONOSON-Basic How to Adjust the Pulse Time (1) Click on the Ti symbol using the Data Selector <2>. The symbol starts flashing. (2) Turn the Data Selector <2>, to adjust the desired pulse time and confirm by pressing it. NOTICE You can only extend the p… |
[Page 31] Physiomed IONOSON-Basic Current Mode MENS: monophase Current Mode MENS: biphase Parameters for Current Mode MENS Polarity switch to switch the polarity of the two electrodes; the sign in the intensity dis- play changes accordingly. Switching from monophase to biphase pulse … |
[Page 32] Physiomed IONOSON-Basic Menu for Current Mode IG30 Current Mode IG30: monophase Current Mode IG30: biphase Parameters for Current Mode IG30 Polarity switch to switch the polarity of the two electrodes ( the sign in the intensity dis- play changes accordingly); can be adjust… |
[Page 33] Physiomed IONOSON-Basic Menu for Current Mode IG50 Current Mode IG50: monophase Current Mode IG50: biphase Parameters for Current Mode IG50 Polarity switch to switch the polarity of the two electrodes ( the sign in the intensity dis- play changes accordingly); can be adjust… |
[Page 34] Physiomed IONOSON-Basic Menu for Current Mode FM Current Mode FM: monophase Current Mode FM: biphase Parameters for Current Type FM Polarity switch to switch the polarity of the two electrodes ( the sign in the intensity dis- play changes accordingly); can be adjusted separ… |
[Page 35] Physiomed IONOSON-Basic 3.3.14 (STOCH) Stochastic Current Definition Stimulation current with random pulse triggering Application • Circulatory stimulation • Analgesia with minimal stimulus adaptation Menu for Current Mode STOCH Current Mode STOCH: monophase Current Mod… |
[Page 36] Physiomed IONOSON-Basic NOTICE You can only change the pulse shape from triangle to square if the intensity in both channels is zero. Square pulses make the current mode more intense. 3.3.15 (FaS) Faradic Surge Current Definition Faradic surge current Application • Treatm… |
[Page 37] Physiomed IONOSON-Basic ately for both channels Pulse time Ti (1 .. 10 ms) and release time Ri (15 .. 150 ms); selection of the current mode, the basic parameters of the neofaradic current are set. Pulse shape (triangle pulse, square pulse) Acoustic signal; makes every puls… |
[Page 38] Physiomed IONOSON-Basic 3.3.16 (T/R) Pulses with Adjustable Parameters Definition Pulses with adjustable parameters Application • Treatment of peripheral paralysis • selective muscle stimulation Menu for Current Mode T/R Current Mode T/R: monophase Current Mode T/R: bip… |
[Page 39] Physiomed IONOSON-Basic 3.4 Medium Frequency Current Modes 3.4.1 (IFM) Modulated Interference Current Definition Medium frequency alternating current that features a outstanding compatibility and significant depth effect. Application • Pain therapy • Circulatory stimula… |
[Page 40] Physiomed IONOSON-Basic NOTICE You can only shorten the release time if the intensity in both channels is zero. How to Program a Frequency Band (1) Click on the symbol by means of the Data Selector <2>. The symbol starts flashing. (2) Turn the Data Selector <2> … |
[Page 41] Physiomed IONOSON-Basic Current Mode AMF: Sinusoidal Waves Parameters for Current Mode AMF Frequency cycle (1 s / 30 s / 1 s; 1 s / 1 s / 1 s; 3 s / 3 s / 3 s; 6 s / 6 s / 6 s; 12 s / 12 s / 12 s; Time upper frequency / Changing time / Time lower frequency) Basic frequency … |
[Page 42] Physiomed IONOSON-Basic How to Adjust a Selective Frequency (1) Click on the symbol by means of the Data Selector <2>. The symbol starts flashing. (2) Turn the Data Selector <2> to the right until the SELECTIVE symbol is displayed. (3) Turn the Data Selector <… |
[Page 43] Physiomed IONOSON-Basic Acoustic signal; makes pulses audible NOTICE Each time the intensity is incremented, the instrument puts out a pulse with a length of about 4 seconds. PHYSIOMED ELEKTROMEDIZIN AG 3 Overview of Current Modes IONOSON-Basic 37 |
[Page 44] Physiomed IONOSON-Basic Chapter 4 Operation of the instrument The operating steps not directly relating to the therapy are described in the following paragraphs. 4.1 Mains and Battery Operation Two IONOSON-Basic models are available: • for mains operation only • for mai… |
[Page 45] Physiomed IONOSON-Basic 4.1.2 Economy Mode In the battery operation mode, the instrument automatically switches over to the economy mode in the start menu to save power. The Display <1> is no longer illuminated. Turning the Data Selector <2> will re-activate the… |
[Page 46] Physiomed IONOSON-Basic In case of a monitoring note, first perform a self-test once or several times (refer to Function Check on page 39), and check if the problem still occurs afterwards. Important Inform your service partner if the monitoring note does not disappear even… |
[Page 47] Physiomed IONOSON-Basic Chapter 5 Therapy with Stimulation Current In this chapter, you will find general information on the therapy with stimulation current and notes to ap- ply electrodes. Furthermore, the properties and operating steps of different types of treatment wit… |
[Page 48] Physiomed IONOSON-Basic 5.2.1 Modes of Attaching the Electrodes The following techniques to attach electrodes are common in stimulation current therapy: Bipolar Here you apply two electrodes of equal size. This is the most common mode especially for pain therapy and circula… |
[Page 49] Physiomed IONOSON-Basic Type Diameter of the Electrode (cm) Effective Area (cm2) Maximum Intensity for Currents with High Galvanic Component (mA) 0 3.0 7 0.7 1 6.0 20 2 2 9.0 40 4 5.4 Preparations and Attaching the Electrodes To prepare the electrodes, proceed as follows: (… |
[Page 50] Physiomed IONOSON-Basic Introduction to stimulation current therapy (ref. no. 00625). 5.5 Therapy Using Low-Frequency Current Modes 5.5.1 Monophase and Biphase Currents The majority of low-frequency current modes for pain therapy, circulatory stimulation, detonisation and m… |
[Page 51] Physiomed IONOSON-Basic Current Mode G The current modes designated for iontophoresis are G and GMC. You find a detailed overview about the parameters adjustable under Parameters for Current Mode G on page 16 and Parameters for Current Mode GMC on page 17. It is important f… |
[Page 52] Physiomed IONOSON-Basic Socket <11> on the front of the instrument and hand the manual release key to the patient. (8) Slowly turn up the intensity of channel I with the Intensity Control Channel I <3>. The therapy time elapses. CAUTION Make sure you do not touc… |
[Page 53] Physiomed IONOSON-Basic How to Perform a Treatment (1) Switch on the instrument. (2) Attach the electrodes to the respective stimulation points. (3) From the Display <1>, select one of the above-mentioned current modes, e.g. STOCH. (4) Select the parameters variable f… |
[Page 54] Physiomed IONOSON-Basic How to Perform a Treatment with Automatic Current Output (1) Switch on the instrument. (2) Attach the electrodes to the respective stimulation points. Position the patient to enable free move- ment of the stimulation area. (3) Depending on the indica… |
[Page 55] Physiomed IONOSON-Basic (9) With the Data Selector <2> first click on the R symbol, rotate to the left until one of the manual control symbols appears and press to confirm. The symbols have the following meaning: • : The duration of increase is determined by pressin… |
[Page 56] Physiomed IONOSON-Basic <3> or Intensity Control Channel 2 <4>), until the muscle contraction is sufficient. The therapy time elapses. CAUTION Make sure you do not touch the electrodes when the current is turned up! When using the manual release key, release a p… |
[Page 57] Physiomed IONOSON-Basic NOTICE This current mode requires both channel I and II at the same time. You cannot select an addi- tional current mode in channel II. How to Perform a Treatment with IFM Current (1) Switch on the instrument. (2) Attach the electrodes to the stimula… |
[Page 58] Physiomed IONOSON-Basic You find a detailed overview about the parameters adjustable under (AMF) Amplitude-Modulated Medi- um-Frequency Current on page 34. NOTICE This current mode can only be applied in channel I. You cannot set a second current mode in channel II. How to … |
[Page 59] Physiomed IONOSON-Basic How to Make a Treatment with Medium Frequency Stimulation Current KOTS (1) Switch on the instrument. (2) Attach the electrodes to the respective stimulation points. Position the patient to enable free move- ment of the stimulation area. (3) Select th… |
[Page 60] Physiomed IONOSON-Basic (8) Select the modulation frequency. (9) If necessary, alter the basic frequency F bas . (10) Activate the acoustic signal if desired. (11) Set the therapy time. (12) Slowly turn up the intensity with the manual release key pressed (Intensity Control… |
[Page 61] Physiomed IONOSON-Basic Chapter 6 Ultrasound Therapy IONOSON-Basic offers you three possibilities to start ultrasound therapy: • directly via the ultrasound menu • via the indications menu (refer to Indications Menu on page 59) • via an individual program (refer to In… |
[Page 62] Physiomed IONOSON-Basic (2) Apply some ultrasound gel on the area of treatment. (3) Choose SONO in the Display <1> . (4) Select the duration of the treatment. (5) Increase the dose to the desired value with the Data Selector <2>. NOTICE To prevent from overdoses… |
[Page 63] Physiomed IONOSON-Basic Chapter 7 Simultaneous Therapy Simultaneous therapy means the treatment with ultrasound and stimulation current at the same time. The ultrasonic transducer is one pole of the stimulation current circuit, a plate electrode the other one. It is advisab… |
[Page 64] Physiomed IONOSON-Basic Simultaneous Therapy You will find a description of the individual symbols in Ultrasound Therapy on page 55. (5) Rotate the Data Selector <2> until you reach the SIM symbol. Now press the Data Selector <2>, rotate it one position further … |
[Page 65] Physiomed IONOSON-Basic Chapter 8 Indications Menu Apart from direct access to the individual current modes, the indications menu offers you another possibil- ity to start the individual methods of treatment. With the indications menu, you may use proven stimula- tion curre… |
[Page 66] Physiomed IONOSON-Basic NOTICE The page number is displayed on the right of the lower status bar. The left number iden- tifies the page selected, the right number the total number of pages. Indications Menu: Attaching the Electrodes (6) Attach the electrodes to the respecti… |
[Page 67] Physiomed IONOSON-Basic Chapter 9 Individual Programs You do not have to set frequently applied forms of therapy every time you want to use them – you can simply save them as individual programs. Such a program is e.g. a certain current mode or an ultrasound therapy with … |
[Page 68] Physiomed IONOSON-Basic (5) Turn the Data Selector <2> to the right and click on the symbol (save program). The symbol flashed and the cursor jumps to the first position of the selected program. (6) Turn the Data Selector <2> to select the desired position and c… |
[Page 69] Physiomed IONOSON-Basic (4) Turn the Data Selector <2> to the right and click on the symbol (delete program). The bin sym- bol flashes and the cursor jumps to the first position of the selected program. (5) Turn the Data Selector <2> to select the desired positi… |
[Page 70] Physiomed IONOSON-Basic Appendix A Annex A.1 Customer Service, Maintenance, Service The manufacturer is responsible only for the original security relevant properties of the instrument. The in- strument must be used generally in conformance with the user manual. Maintenance… |
[Page 71] Physiomed IONOSON-Basic A.4 Electromagnetic Compatibility Declaration in accordance with standard EN 60601-1-2: Electromagnetic compatibility Medical electrical devices are subject to particular precautions regarding electromagnetic compatibility and must be used in accorda… |
[Page 72] Physiomed IONOSON-Basic A.7 Basic Settings In the Basic Settings menu, you can adjust the following instrument parameters: Symbol Meaning Contrast of the Display <1> Power threshold at which the instrument switches from continuous to pulsed power out- put in continuou… |
[Page 73] Physiomed IONOSON-Basic A.8 Technical Data General Technical Data Protection class acc. to IEC 60601-1/ VDE 750 Teil1 I, type: BF CE characterization acc. to Council Directive concerning medical devices (93/42 EEC) Class acc. to Council Directive concerning medical devices … |
[Page 74] Physiomed IONOSON-Basic Ultrasound Frequency 1 MHz 3 MHz BNR <= 6 <= 6 Bundle type Diverging Diverging Modulation Continuous ultrasound cont. Pulsed ultrasound: duty cycle (impulse/pause) 1:10; 1:5; 1:3; 2:5 Pulsed ultrasound: pulse frequency 100 Hz Adjustable switchi… |
[Page 75] Physiomed IONOSON-Basic Appendix B Scope of Delivery and Accessories Important For safety reasons, the instrument is to be used exclusively with original accessories. The use of other manufacturers’ accessories is at the user’s risk! Important Plate electrodes are… |
[Page 76] Physiomed IONOSON-Basic B.2 Scope of Delivery (Battery-Operated Model) IONOSON-Basic as battery-operated model is supplied with the following accessories: Ref. No. Designation Quantity 02004 Combination therapy instrument IONOSON-Basic (battery-operated model) 1 00776 Mains… |
[Page 77] Physiomed IONOSON-Basic Art.-No. Designation 00184 Filling pump 00413 Glove electrode (pair) 00156 Grip handle for electrodes with pushbutton 00155 Grip handle for electrodes 00136 Iontophoresis foil 18 x 12 cm; 1000 items 00776 Mains cable 00775 Mains cable short 00344 Man… |
[Page 78] Physiomed IONOSON-Basic Art.-No. Designation 00656 Plate electrode EF100 / 12 x 9 cm (red/blue) 00535 Plate electrode EF100 / 12 x 9 cm (red/red) 00565 Plate electrode EF100 / 12 x 9 cm (red/red) 1,5 m 00658 Plate electrode EF100 / 12 x 9 cm (set of 4) 00536 Plate electrode… |
[Page 79] Physiomed IONOSON-Basic Art.-No. Designation 00439 Viscose cover EF200 / 20 x 14 cm 00464 Viscose sponge for bow electrode Ø 2.0 cm 00463 Viscose sponge for bow electrode Ø 4.5 cm PHYSIOMED ELEKTROMEDIZIN AG Scope of Delivery and Accessories IONOSON-Basic 73 |
[Page 80] Physiomed IONOSON-Basic Appendix C Supplementary Documents C.1 Manufacturer’s Recommendations �… |
[Page 81] Physiomed IONOSON-Basic Index A accessories available 70 alternating stimulation 12 ambient temperature 67 AMF (current mode) 34 application 4 automatic switch-off output current 7 B basic settings 66 batteries handling 38 battery operation 38 biphase current modes 44 C cal… |
[Page 82] Physiomed IONOSON-Basic GMC (current mode) 16 H high-voltage current 21 HV (current mode) 21 hyperaemisation 46 I IFM (current mode) 33 IFM current therapy 50 IG30 (current mode) 25 IG50 (current mode) 26 indications 4 , 59 indications menu 59 indicators 6 instrument descri… |
[Page 83] Physiomed IONOSON-Basic stimulation alternating 12 simultaneous 12 stimulation current therapy medium frequency current modes 50 therapy using low-frequency current modes 44 stimulation currents medium frequency 52 STOCH (current mode) 29 stochastic current 29 surge current… |