Printing Recorder with text printing and LED dot-matrix display B 70.6030.0 Operating Manual 2009-06-03/00353037… -
Page 2
Key functions — Paper (chart) fast-forward, when recording is stopped (in basic status) — Abort parameter entry (Exit) — Leave the levels — Start/Stop of recording — Selection of decimal point position when entering values — For text entry: Fast character selection (jump to “… -
Page 3: Table Of Contents
Contents Introduction Preface ………………….7 Arrangement of the documentation …………8 1.2.1 Structure of this operating manual …………… 8 Typographical conventions ……………. 9 1.3.1 Warning signs ………………..9 1.3.2 Note signs ………………… 9 1.3.3 Presentation ………………..10 Instrument description Display and controls …………….11 Basics of operation ……………….
-
Page 4
Contents Colour assignment ………………. 51 Relationship between measurement range and scaling ……. 52 Configuration table Operating examples …………….. 53 Table of the configuration parameters ……….. 55 4.2.1 Operating level (S-level) …………….55 4.2.2 Parameter level (P-Level) …………….56 4.2.3 Configuration level 1 (C1-level) …………..57 4.2.4 Configuration level 2 (C2-level) ………….. -
Page 5
Contents Removing and replacing the chart cassette ………. 86 9.2.1 Changing the roll chart …………….88 9.2.2 Changing the fanfold chart …………….. 89 Extra codes and accessories 10.1 Converting the chart cassette …………..91 10.2 “8 logic inputs”, “interface for ER8”, “voltage output”… -
Page 6
Contents… -
Page 7: Introduction
You could endanger your rights under the warranty! Please contact the nearest JUMO office or the head office. When returning modules, assemblies or components, the regulations of EN 61340-5-1 and EN 61340-5-2 “Protection of electronic devices from electrostatic phenomena”…
-
Page 8: Arrangement Of The Documentation
1 Introduction Arrangement of the documentation The documentation for this instrument consists of the following parts: Operating This operating manual is always supplied with the instrument. It is addressed Manual to OEMs (original equipment manufacturers) and users with the appropriate B 70.6030.0 technical know-how.
-
Page 9: Typographical Conventions
1 Introduction Typographical conventions 1.3.1 Warning signs The signs for Danger and Warning are used in this manual under the following conditions: Danger This symbol is used where there may be danger to personnel if the instructions are disregarded or not followed accurately! Warning This symbol is used where there may be danger to equipment or data if the instructions are disregarded or not followed accurately!
-
Page 10: Presentation
1 Introduction 1.3.3 Presentation Keys Keys are shown in a box. Both symbols and texts are possible. If a key has multiple functions, then the text shown is that which corresponds to the currently active function. Screen texts Program Texts which are displayed in the setup program are distinguished by italic Manager script.
-
Page 11: Instrument Description
2 Instrument description 2.1 Display and controls Fault signal LED This lights up as soon as the recording is interrupted by the “end of chart paper”, “stop” through pressing stop key S , or by an external stop. 24-character green LED Setup interface dot-matrix display (behind the swing-up…
-
Page 12: Basics Of Operation
2 Instrument description 2.2 Basics of operation In order to keep the operating and programming of the printing recorder clear and simple, the individual parameters and functions are divided into several levels: — Basic status — Operating level (S-level) — Parameter level (P-level) — Configuration level 1 (C1-level) — Configuration level 2 (C2-level) — Configuration level 3 (C3-level)
-
Page 13
2 Instrument description Basic status Operating level after correct functions code number in parameter and configuration levels Chart fast-forward, -Abort parameter -Abort parameter when recording is entry entry stopped (Exit) -Leave the level -Leave the level Start/stop Start/stop Step recording mode recording mode -for values: Select the… -
Page 14
2 Instrument description For all alterations to the parameters (sub-parameters): If there are no further sub-parameters available, then E transfers all the Confirmation of parameters data which belong to the parameter into the memory. Inside a parameter, programming can be abandoned by pressing the e key. Abort programming If the last sub-parameter has not been confirmed, then the data… -
Page 15
2 Instrument description Value/text Five keys are used to enter values: entry h select the position to be altered, using the l and r keys h increment and decrement the selected position with the h and R keys h move the decimal point with the S key h confirm the value entered with E An erroneous entry will cause an error message in the display v Section 12.1 “Error messages”… -
Page 16
2 Instrument description Key inhibit If the printing recorder is fitted with the extra code “logic inputs”, then it is possible when a selected logic input is closed, in connection with the parame- ter Configuration level 3 Inhibit keys, to inhibit the recorder keys. The following keys or functions can be inhibited in the basic status: chart fast-forward, when the recording mode is stopped start/stop of recording mode… -
Page 17
2 Instrument description Basic status After the supply voltage has been applied, the printing recorder will be initial- ised and is then in the basic status. Measurements are made, processed, and recorded. The 24-character LED dot-matrix display can show: — instrument designation (name), date and time (the time can be switched off via the parameter Parameter level Display time) -
Page 18
2 Instrument description Example of the basic status for a 6-channel recorder BUILDING28 03.11.98 08 : 54 Display instrument name, date and time 1 -5.321m/h 2 +34.67°C Display the first 2 channels in one frame 3 +76.20°C 4 +20.35bar Display the next two channels in one frame 5 +35.08°C 6 +007.4U/m Display the next two channels in one frame… -
Page 19
The code numbers can be altered through the setup program (Edit Code numbers …) or on the instrument. v Section 4.2 “Table of the configuration parameters” If customer-specific code numbers are entered, then the original JUMO code numbers will be overwritten, and are no longer valid. -
Page 20
2 Instrument description If the same figures are used for both code numbers, then these code numbers will be interpreted as code numbers for the com- plete parameter set. The relays in the external relay module ER8 remain in their present state. -
Page 21
2 Instrument description Configuration Configuration level 2 can be accessed from configuration level 1 with the aid of the h + R keys, or from configuration level 3 by using e. level 2 (C2-level) If a correct code number is entered when calling up the parameter level, then the signal acquisition and recording will be interrupted in this level. -
Page 22
2 Instrument description Configuration Configuration level 3 can be accessed from configuration level 2 with the aid of the h + R keys. level 3 (C3-level) If a correct code number is entered when calling up the parameter level, then the signal acquisition and recording will be interrupted in this level. -
Page 23: Operation And Visualisation
3 Operation and visualisation The printing recorder has a large variety of possibilities for presenting the measurements acquired at the signal inputs on the paper, for monitoring them, and for control. The functions are available for: — limit monitoring through limit comparators — open-collector outputs — different chart paper speeds — graphics printing…
-
Page 24
3 Operation and visualisation LK function: lk8 As well as producing the text print-out, the results from — limit comparators 1 to 3 can be fed to the open-collector outputs 1 to 3, and/or — those from limit comparators 1 to 8 to the relay outputs 1 to 8 (option). The relay outputs are available as an option (extra code ER8). -
Page 25: Open-Collector Outputs
3 Operation and visualisation 3.2 Open-collector outputs The printing recorder is equipped with four open-collector outputs. The out- puts 1 to 3 have a fixed assignment to the limit comparators 1 to 3. Output 4 is used as a fault signal output. The outputs can be activated by using the pa- rameter Configuration level 2 Open-collector.
-
Page 26: Different Chart Speeds (Paper Feed)
3 Operation and visualisation 3.3 Different chart speeds (paper feed) The printing recorder is equipped with several different chart speeds, so that the measurements can always be optimally interpreted on the chart. Normal chart The chart paper is transported with the speed which is programmed in the pa- speed rameter Operating level Chart speed.
-
Page 27: Graphic Print-Out
3 Operation and visualisation 3.4 Graphic print-out The printing recorder is fitted with a print head which always has 6 colour pens, regardless of the number of channels. For the 3-channel version the col- our sequence is: violet, red, black, violet, red, black. For the 6-channel version it is: violet, red, black, green, blue, brown.
-
Page 28
3 Operation and visualisation Example: If three traces lie on top of one another, then the alternating print pattern en- sures that no point has a multiple print, but that each channel uses one point at a time, sequentially. -
Page 29: Measurement Traces (Signal Traces)
3 Operation and visualisation 3.4.1 Measurement traces (signal traces) In the factory setting, all the measurement traces are printed over the full chart width. The parameters “zoom” and ”presentation range” offer the possibility of altering the print-out. Zoom Zoom operation is used to record a section of the complete measurement (plot area) range in an enlargement.
-
Page 30: Event Traces
3 Operation and visualisation These minimum and maximum values are printed when peak value recording is activated. One advantage of the peak value recording is that at least an im- pression of the measurement trace on the chart can be gained, even at slow chart speeds and after text printing in the “Interrupt measurement trace”…
-
Page 31: Text Printing
3 Operation and visualisation 3.5 Text printing As well as the traces of the chart, the recorder can also print text. Text printing is used to make comments on the traces and for recording events. The char- acters are printed in dots in a 7 x 9 matrix. 3.5.1 Printing priorities There are different kinds of text which can have priorities and a printing mode…
-
Page 32
3 Operation and visualisation Time Text-print request the actual text printed is: 12:07 12:06 12:02 Limit exceeded 12:05 12:04 12:03 12:02 Limit exceeded Report 12:01 12:00 Report If texts with the same priority cannot be printed at once, then the order in which they will be printed is not determined by the order in which the corre- sponding events occurred, but is determined by an internal order of prece- dence in the recorder. -
Page 33
3 Operation and visualisation In the following cases, all current request for text printing will be cancelled, and any fresh ones will be ignored: — Recorder goes into the stop status — Recorder is switched off One exception to this rule is the report. v Section 3.5.5 “Report”… -
Page 34: Printing Modes
3 Operation and visualisation 3.5.2 Printing modes Texts can be printed in two modes: — by interrupting the measurement trace (Outplot) — overwrite the measurement trace (Inplot) Interrupt The text is printed as fast as possible. During the text printing there is no re- measurement cording of measurements or event traces.
-
Page 35: Queuing During Text Printing
3 Operation and visualisation Disadvantages: — the text printing can take a very long time — the printing of other texts is blocked — text printing is not possible at a chart speed of 0mm/h. 3.5.3 Queuing during text printing External texts, binary-linked texts, limit comparator texts for going above and below limit values, as well as event texts, are printed through a queue.
-
Page 36: Limit Comparator Texts, External Text, Binary-Linked External Text
3 Operation and visualisation 3.5.4 Limit comparator texts, external text, binary-linked external text Limit Limit comparator texts can be printed out. To do this, the parameter Configu- comparator ration level 1 Limit comparator Limtext state must be set to ON and the texts corresponding texts must be entered.
-
Page 37
3 Operation and visualisation Binary no. Decimal no. /text 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 1. logic input 4. logic input Activation is carried out by the parameter Configuration level 3 Text logic links. -
Page 38: Report
3 Operation and visualisation 3.5.5 Report The report is used to create statistics about the measurements, referred to a definable period of time (statistical period). The minimum, maximum and average values of the measurements are calcu- lated for the statistical period. The result is printed out at the end of the statis- tical period, in the form of a table.
-
Page 39
3 Operation and visualisation External report The external report is controlled by a selectable logic input. In addition to the parameter Configuration level 2 Report (EXTERN.CONTACT), the logic input which is wanted must be selected through the parameter Configuration level 3 External report (e.g. -
Page 40
3 Operation and visualisation General For the report: — If the printing recorder is switched off at the end of the statistical period, then the print-out will be completely cancelled. The same applies if the instrument is re-configured from the keys, or if the setup connector is plugged in. -
Page 41: Switching The Chart Speed
3 Operation and visualisation 3.5.6 Switching the chart speed Every change of chart speed is recorded by printing out a line with the time of the change and the new chart speed, if the parameter “Print chart speed” is set to ON in Configuration level 2 Print speed change.
-
Page 42: Power On» And «Power Off» Texts
3 Operation and visualisation Fixing the printing priority applied to the text for Speed change- over affects not only the print-out of the marking at change-over, but also the change-over itself. v Section 3.5.1 “Printing priorities” As long as a text with a higher priority is being printed, a change- over will not happen if the parameter Configuration level 2 Print speed change is set to ON.
-
Page 43: Scaling
3 Operation and visualisation 3.5.8 Scaling The scaling can be printed in two different ways: cyclic: for each channel, at a configurable spacing (Configuration level 2 Print scale) triggered: for each channel, when the F-key is pressed for at least 4 sec, or by closing a logic input (Configuration level 3 External scaling)
-
Page 44
3 Operation and visualisation Example: — Channel 3 — Presentation range: 0 — 100mm — Limit comparator thresholds at 200 and 500°C Example: — Channel 2 — Presentation range limited to: 50 — 100mm — Limit comparator threshold at 300V… -
Page 45
3 Operation and visualisation To start the triggered scaling print, the F-key must be pressed for at least 4 Triggered scaling print seconds. Alternatively, the triggered scaling print can be initiated by a logic input (extra code). The scalings are printed out for all channels with an activated plot status. The print-out is made up in the same layout as described for “Cyclic scaling print”. -
Page 46: Time
3 Operation and visualisation 3.5.9 Time The print-out is performed cyclically, at a configurable spacing (Configuration level 2 Print time). Selectable spacings: — approx. 2cm — approx. 4cm — approx. 6cm — not time printing The spacings do not depend on the paper feed which has been set up. The spacings listed above are only approximates, since the print is made at round values of time.
-
Page 47: Print Out Channel Numbers
3 Operation and visualisation 3.5.10 Print out channel numbers In order to be able to associate measurements more clearly with a channel, the channel number can be printed next to the trace, in the channel colour. The print-out is made cyclically, at a configurable spacing (Configuration level 2 Print channel numbers).
-
Page 48: Incrementing The Two Event Counters
3 Operation and visualisation 3.5.12 Incrementing the two event counters The event counter is assigned to a freely selected logic input. Every time the corresponding logic input is closed, the event counter is incremented. It can be pre-loaded with a value through the setup program and the keys on the re- corder (Configuration level 3 Event counter).
-
Page 49: Print Test
3 Operation and visualisation 3.5.13 Print test The print test can only be initiated from the keys on the printing recorder (Op- erating level Print test). It is used to test the function of the printing system and the print head. The print test carries on until it is stopped by Test print = Off.
-
Page 50: Service Print
3 Operation and visualisation 3.5.14 Service print The service print can only be initiated from the keys on the printing recorder (Operating level Service print). The print-out consists of: — the current date and time — the software version — the number of mains power supply interruptions — the total operational time of the recorder in hours — the current state of the two event counters — the minimum and maximum ambient temperatures of the internal Pt100…
-
Page 51: Colour Assignment
3 Operation and visualisation 3.6 Colour assignment With the aid of the setup program you can select the colours which are used for print-outs. Selections can be made for: — Measurement traces — Event traces — Instrument name — External text — Binary-linked external text — Even texts, event counters Texts which are associated with a channel (e.g.
-
Page 52: Relationship Between Measurement Range And Scaling
3 Operation and visualisation 3.7 Relationship between measurement range and scaling The printing recorder offers the facility to differentiate between the measure- ment range for the input signals which are connected and the scaling on the chart paper. If the parameter Configuration level 1 Measurement input Characteristic is not programmed to linear, X1 or X2, then the selected measurement range is…
-
Page 53: Configuration Table
4 Configuration table 4.1 Operating examples Example 1 The date, time and weekday are to be programmed. Display Description 5 AMB. TEMP. +35.08°C Recorder is in basic status h + R Call up operating level S-LEVEL (now in operating level) h + R Start code check Enter 9200, by using the l, r, h, R…
-
Page 54
Call 1st. parameter of this level UNIT NAME (the name of the instrument) Call the parameter to be altered TEXT: LOGOPRINT 500 Enter the new designation (UNIT NAME), using the l, r, h, R and S keys Confirm instrument designation… -
Page 55: Table Of The Configuration Parameters
4 Configuration table 4.2 Table of the configuration parameters All the parameters for the instrument are presented in the following table. The parameters are explained in the order in which they appear in the recorder. The first column of the table shows the path through the levels to the particular parameter.
-
Page 56: Parameter Level (P-Level)
4 Configuration table 4.2.2 Parameter level (P-Level) Parameter Value/selection Description Language Parameter level Select language Language Language: ENGLISH The language setting GERMAN affects all the non- FRENCH programmable texts in the recorder which can be displayed or printed out. Date & time Parameter level Programming the Date &…
-
Page 57: Configuration Level 1 (C1-Level)
4 Configuration table 4.2.3 Configuration level 1 (C1-level) Parameter Value/selection Description Plot status Configuration level 1 Setting for each writing Plot status channel: should the signal X Plot status 1 — 3 or 1 — 6 trace be printed on the chart and appear in the Status: ON, OFF…
-
Page 58
4 Configuration table Parameter Value/selection Description Range start: -9999 to +9999 Enter start of measurement range Range end: -9999 to +9999 Enter end of Meas. span ≥ 100°C measurement range for Type S, R, B ≥ 500°C Cold junction: INTERN Pt 100 Select cold junction (temp. -
Page 59
4 Configuration table Parameter Value/selection Description 0 ≤ Re ≤ 4000Ω End res. Re: Enter end resistance Ra + Rs + Re ≤ 4000Ω Meas. span ≥ 6Ω Filter: 0.0 — 50.0sec Enter filter constant Configuration level 1 X1 = customer-specific Measurement input linearisation 1 Type: voltage… -
Page 60
4 Configuration table Parameter Value/selection Description Range end: -9999 to +9999 Enter end of measurement -20mA < rge. end ≤ 20mA range Meas. span ≥ 0.5mA Temperature: °C, °F (only for thermocouples (dimension) and resistance thermometers) Temp. start: -9999 to +9999 Enter start of temperature range (only for thermocouples… -
Page 61
4 Configuration table Parameter Value/selection Description Limit comparator Configuration level 1 Limit comparator X Limit comparator 1 — 8 Select limit comparator Limit value: -9999 to +9999 Enter value for limit Lower differential: 0 — 9999 Enter the hysteresis below the limit value Upper differential: 0 —… -
Page 62
4 Configuration table Parameter Value/selection Description Zoom Configuration level 1 Zoom X Zoom 1 — 3 or 1 — 6 Select reference channel Low: 0 — 90 Enter measurement value for start (in % of measure- ment range) High: 10 — 100 Enter measurement value End –… -
Page 63: Configuration Level 2 (C2-Level)
4 Configuration table 4.2.4 Configuration level 2 (C2-level) Parameter Value/selection Description Unit name Configuration level 2 Unit name Text: 16 characters Enter instrument designation Open-collector Configuration level 2 output Open-collector output X Output 1 — 4 Select open-collector output Status: OFF, ON Enter status Speed in limit…
-
Page 64
4 Configuration table Parameter Value/selection Description Print the time Configuration level 2 Determine the regular in- Print time terval at which the time Spacing: OFF, 2, 4, 6cm should be printed in the chart Print the Configuration level 2 Determine the interval for channel numbers Print channel numbers printing the traces in the… -
Page 65
4 Configuration table Parameter Value/selection Description Start text Configuration level 2 Start text Status: OFF, ON Select the status for the print-out of the start text (if OFF: text entry not required) Text: 16 characters Enter start text End text Configuration level 2 End text Status:… -
Page 66: Configuration Level 3 (C3-Level)
4 Configuration table 4.2.5 Configuration level 3 (C3-level) Parameter Value/selection Description Relay output Configuration level 3 Relay output X Relay 1 — 8 Select relay Status: OFF, ON OFF = relay inactive ON = relay operates as an LK output Mathematical Configuration level 3 module…
-
Page 67
4 Configuration table Parameter Value/selection Description Text logic links 00 — 01 (Log. input 1) Select binary combination 00 — 03 (Log. input 1-2) (text-no.) 00 — 07 (Log. input 1-3) 00 — 15 (Log. input 1-4) Text status: OFF, ON Select the status for the text printing Text:… -
Page 68
4 Configuration table Parameter Value/selection Description External report Configuration level 3 External report X External report 1 — 2 Select report/instance number Contact: OFF, Log. input 1, Select logic input Log. input 2, Log. input 3, Log. input 4, Log. input 5, Log. -
Page 69: Identifying The Instrument Version
5 Identifying the instrument version 5.1 Instrument description The printing recorder is equipped with 3 or (optionally) 6 signal inputs, which are electrically isolated from one another. The evaluation of the measurement traces of the printing recorder can be assisted by printed texts. The programming of the instrument is possible either by using the 8 keys on the front of the instrument or through a PC setup program.
-
Page 70: Order Details
5 Identifying the instrument version 5.2 Order details (1) Basic version 706030/14 LOGOPRINT 500 with 3 universal inputs 706030/15 LOGOPRINT 500 with 6 universal inputs (2) Inputs 1 — 3 (configurable) factory setting configuration to customer specification (3) Inputs 4 — 6 (configurable)
-
Page 71: Installation
6 Installation 6.1 Site and climatic conditions The installation site should be as free as possible from vibration. Stray electro- magnetic fields, for instance those caused by motors, transformers and the like, should be avoided where possible. The ambient temperature at the installation site must not go outside the range 0 to +50°C, at a relative humidity of 20 —…
-
Page 72
6 Installation h Insert the recorder from the front into the panel cut-out. Mounting h From the back of the panel, hook the two mounting brackets into the cut- outs in the sides of the housing. The flat faces of the brackets must lie against the housing. -
Page 73: Electrical Connection
7 Electrical connection 7.1 Installation notes The rules of VDE 0100 “Regulations for the installation of high-current equipment with rated voltages below 1000V” or the equivalent national standards must be observed for the selection of cables, installation and electrical connection of the instrument. Internal work on the instrument may only be carried out by properly qual- ified personnel, and then only to the extent described.
-
Page 74: Technical Data
7 Electrical connection 7.2 Technical data Thermocouple Measurement range Linearisation accuracy input Fe-Con L -200 to +900°C ±0.2% Fe-Con J EN 60584 -210 to +1200°C ±0.2% above -200°C Cu-Con U -200 to +600°C ±0.3% Cu-Con T EN 60584 -270 to +400°C ±0.5% above -200°C NiCr-Ni K EN 60584…
-
Page 75
7 Electrical connection Range start/end freely programmable within the limits, in 0.1°C steps Measurement time for 3 channels < 2sec; for 6 channels < 4sec Input filter 2nd. order digital filter; filter constant adjustable from 0 to 50sec Features also programmable in °F; customer-specific linearisation Input from Measurement range Accuracy… -
Page 76
7 Electrical connection Short-circuit Break Voltage above ± 1V not recognised not recognised Current not recognised not recognised 1. The print head is positioned to 0% , “>>>>>>” appears in the LED dot-matrix display. 2. In 4-wire circuit: only recognised at terminals 1 and 2. Outputs 3 open-collector to signal over/under limit… -
Page 77
7 Electrical connection Power consumption max. 35VA Data buffering Through a lithium battery in RAM > 4 years, or with a storage capacitor: 2 days at 15 to 25°C ambient temperature. Additional backup in EEPROM. Electrical connection At rear through plug-in screw terminals, conductor cross-section max. -
Page 78: Connection Diagram
7 Electrical connection 7.3 Connection diagram Rear view of 3/6-channel version Terminal assignment Terminal symbol 3/6-channel version Supply as on label N neutral field L1 line PE earth Analogue inputs Inputs field Thermocouple Resistance 1. 2. 3. 4. 5. 6. thermometer in 2-wire circuit Resistance…
-
Page 79
7 Electrical connection Analogue inputs Inputs field Resistance thermometer in 4-wire circuit Resistance transmitter with 3-wire connection A = start S = slider E = end Potentiometer 2-wire circuit Potentiometer in 3-wire circuit Potentiometer 1. 2. 3. 4. 5. 6. in 4-wire circuit Voltage input ≤… -
Page 80
7 Electrical connection External relay Communication Field module ER8 with external relay module Voltage source 24V / 45mA for external ± 5% 2-wire transmitter Logic operating Contact operation inputs LOW = ≥ 100kΩ HIGH = ≤ 50kΩ min. pulse length: Voltage operation HIGH 400msec LOW =… -
Page 81: Electrical Isolation
7 Electrical connection 7.4 Electrical isolation…
-
Page 82
7 Electrical connection… -
Page 83: Starting Up
8 Starting up 8.1 Opening and closing the door Turn the knob to open or close the door, . 8.2 Marking the channel label After the door has been opened, the measurement channel designation label can be removed and marked, as required, with the channel specific data, such as measurement range, zoom, and presentation range.
-
Page 84: Fitting The Print Head
8 Starting up 8.3 Fitting the print head h Open the door h Stop recording (press the S key) In the stop state, the print head is always moved to the middle of the recording band. h Swing the display radially upwards h Push the print head into the holder, up to the stop h Swing the display downwards, until it snaps into place h Start recording again (press the S key)
-
Page 85: Consumables
9 Consumables 9.1 Consumables Print head 3 colours for 3-channel recorder Packing unit: 2 pieces Part No.: 00355244 6 colours for 6-channel recorder Packing unit: 2 pieces Part No.: 00355255 Roll chart paper no name, % graduation, linear overall length: 16m overall width: 120mm Packing unit: 5 rolls Part No.: 00331497…
-
Page 86: Removing And Replacing The Chart Cassette
9 Consumables 9.2 Removing and replacing the chart cassette…
-
Page 87
9 Consumables — When inserting the chart cassette, take care that it is centered on the tear-off edge and – guiding it with the thumb and index finger – insert it into the cassette slot and push it up gently, until the holding/ejector catch snaps into position. -
Page 88: Changing The Roll Chart
9 Consumables 9.2.1 Changing the roll chart…
-
Page 89: Changing The Fanfold Chart
9 Consumables 9.2.2 Changing the fanfold chart 15 cm 10 cm 5 cm * * * * * * * * * * * * * * * * * * * * ENDE…
-
Page 90
9 Consumables… -
Page 91: Extra Codes And Accessories
10 Extra codes and accessories 10.1 Converting the chart cassette…
-
Page 92: Logic Inputs», «Interface For Er8», «Voltage Output
10 Extra codes and accessories 10.2 “8 logic inputs”, “interface for ER8”, “voltage output” The Extra Code provides 8 logic inputs, the serial interface for the external re- lay module ER8, and an electrically isolated power supply for 2-wire transmit- ters.
-
Page 93: External Relay Module Er8
10 Extra codes and accessories 10.3 External relay module ER8 The external relay module ER8 adds 8 switching outputs to the recorder. The sequence of the relays 1 — 8 is permanently assigned to the limit compa- rators 1 — 8 (limit state). The corresponding limit state is only transferred to the relay if the relay has been activated (Configuration level 3 Relay output Status = ON).
-
Page 94
10 Extra codes and accessories Connections to ER8 L1 N (L+) (L-) Power ER 8 Error RxD RxD TxD GND… -
Page 95: Setup Program
10 Extra codes and accessories 10.4 Setup program The setup program provides convenient configuration of the recorder, using an IBM-compatible PC. In addition, the following functions are available for operating and program- ming the printing recorder: — setting different print colours — print mode and priorities — determining which parameters can be set on the printing recorder — settings can be printed out, using the setup program…
-
Page 96
10 Extra codes and accessories The setup program is installed by means of an installation program for Micro- soft Windows. The operation of the setup program is described in the Installation Manual (B 70.6030.3) and in Windows Online Help. All the parameters of the printing recorder can be programmed with the aid of the setup program. -
Page 97: Mathematics And Logic Module
10 Extra codes and accessories 10.5 Mathematics and logic module If the maths/logic module is de-activated, then the signals which are measured at the signal inputs are recorded according to the configuration of the inputs. If the maths/logic module is activated, then the measured signals can be mathe- matically linked.
-
Page 98: Interface (Rs422/Rs485)
10 Extra codes and accessories 10.6 Interface (RS422/RS485) This interface is used for communication with higher-level systems (e. g. bus systems). It is not the same as the setup interface, which is used to transfer the data between the setup program and the recorder. With the aid of the interface it is possible to implement the following functions: — read out measurements from the recorder — monitor the operating status of the recorder…
-
Page 99: Fault-Finding
11 Fault-finding 11.1 What to do if … Display or printing — The value is outside the measuring range (out-of-range) “>>>>>>” — The transducer has been connected up incorrectly — The signal inputs are configured incorrectly — Probe break Instead of a value — The value can no longer be represented: alter the scaling with the setup program, “…
-
Page 100
11 Fault-finding Chart paper is not moving — The chart cassette has not been fitted correctly vSection 9.2 “Removing and replacing the chart cassette” — The take-up roll has not properly engaged with the chart cassette vSection 9.2.1 “Changing the roll chart” — The chart speed has been programmed to 0mm/h vSection 4.2 “Table of the configuration parameters”… -
Page 101: Appendix
Error or fault in recorder LOW BATTERY! — The battery for the real-time clock and for buffering the RAM is discharged. — Please contact the nearest JUMO office or the main factory. ADJUST TIME! — This error message is produced if the storage…
-
Page 102
12 Appendix Display Cause / Remedy Error in parameter entry! ERROR! — Chart speed is outside the range 0 — 720mm/h. The entry must be made again. Enter a value which is within the range. — Date is invalid. An invalid date has been entered. The entry must be made again. -
Page 103: Hardware Fault
The relay will react as in the event of a probe break . The instrument no longer responds to any kind of event, and cannot even be operated or controlled. Please contact the nearest JUMO office or the main factory. Display Cause / Remedy…
-
Page 104: Status Messages
12 Appendix 12.3 Status messages The following status messages are indicated in the LED dot-matrix display: Display Description INITIALISATION — The printing recorder is being initialised. STOP — The recorder is in the stop status, because the S key has been pressed. EXTERNAL STOP — The recorder is in the stop status, because the “external stop”…
-
Page 105: Character Set
12 Appendix 12.4 Character set 0126 0212 Ô 0161 ¡ 0213 Õ » 0162 ¢ 0214 Ö 0163 £ 0215 × 0164 ¤ 0216 Ø 0165 ¥ 0217 Ù & 0166 ¦ 0218 Ú ’ 0167 § 0219 Û 0168 ¨…
-
Page 106: Summary Of The Parameters
12 Appendix…
-
Page 107
12 Appendix… -
Page 108
12 Appendix… -
Page 109: Index
13 Index abort programming – – analogue inputs basic status binary-linked external text change of chart speed channel name channel number character set chart cassette chart speed (paper feed) chart speed, change of code number colour assignment configuration level 1 (C1-level) configuration level 2 (C2-level) configuration level 3 (C3-level) confirmation of parameters…
-
Page 110
13 Index event traces external report external scaling external speed external stop external text extra codes fanfold chart fault signal LED fault signal output fault-finding feed time – filter graphic print-out input installation installation notes installation site instrument description instrument name instrument operation interface interrupt measurement trace… -
Page 111
13 Index masking mathematical module measurement input – measurement range note signs open-collector – operating examples operating level – – out-of-range overrange overwrite measurement trace panel assembly parameter level (P-level) peak value recording plot status power off power on presentation presentation range print head print speed change… -
Page 112
13 Index service print setup program S-level software version speed in limit operation start text start-up static display summer time – technical data text logic links text printing time timed operation underrange unit name value/text entry version number voltage output warning signs warranty word and number… -
Page 116
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc. Street address: JUMO House 8 Technology Boulevard Moritz-Juchheim-Straße 1 Temple Bank, Riverway Canastota, NY 13032, USA 36039 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-697-JUMO Delivery address:…
Key functions
e
— Paper (chart) fast-forward,
when recording is stopped
(in basic status)
— Abort parameter
entry (Exit)
— Leave the levels
S
— Start/Stop
of recording
— Selection of decimal point
position when entering values
— For text entry:
Fast character selection
(jump to » «, «0», «A», «a», «°»,
2″
«
F
— Function key for special
functions
(press for at least 4sec)
factory setting:
print the scaling
l, r
— Shift cursor left/right
(selecting position)
h, R
— Select display:
— Instrument designation,
date & time
— Measurements of the
channels
— System status
— Parameter selection
— Channel selection
— Value selection
from a table of values
— Increment/decrement
present digit
E
— Initiate parameter entry
— Confirm entry
— Acknowledge error message
— Activate/de-activate statistical
display (in basic status)
l + r
— Activate/de-activate the
display of status/error
messages
h + R
— Change to next level
, «À», «à»)
Page 1 — Operating Manual
Printing Recorderwith text printing andLED dot-matrix displayB 70.6030.0Operating Manual2009-06-03/00353037
Page 2
1 Introduction101.3.3 Presentation h + EKeys Keys are shown in a box. Both symbols and texts are possible. If a key hasmultiple functions, then th
Page 3 — Contents
11 Fault-finding100Chart paper is not moving — The chart cassette has not been fitted correctlyvSection 9.2 “Removing and replacing the chart cassette
Page 4
10112 Appendix12.1 Error messages All error messages are displayed by flashing in the LED dot-matrix display atregular intervals. The other instrument
Page 5
12 Appendix102Error in parameter entry!ERROR! — Chart speed is outside the range 0 — 720mm/h. The entry must be made again.Enter a value which is with
Page 6
10312 Appendix12.2 Hardware faultIf one of the following faults occurs, then the recording is aborted and the errormessage will be shown in a flashing
Page 7
12 Appendix10412.3 Status messagesThe following status messages are indicated in the LED dot-matrix display:Display DescriptionINITIALISATION — The pr
Page 8
10512 Appendix12.4 Character setThe characters which can be accessed with the S key (quick selection) areshown on a black background.032 079O0126~0212
Page 9
12 Appendix10612.5 Summary of the parametersParameter Description ProgrammingS = via setupR = on recorderChart speed Chart speed in mm/h R, SPrint tes
Page 10 — 1 Introduction
12 Appendix107Unit name-colourDesignation of the printing recorderColour of the instrument designationR, SSOpen-collector output Status (on /off) for
Page 11 — 2 Instrument description
12 Appendix108Relay outputs Status (on/off) for each relay of the external relay module R, SMathematical/logic moduleActivate/de-activate the module R
Page 12
10913 IndexAabort programming 14analogue inputs 74–75, 78–79, 106Bbasic status 17binary-linked external text 36, 66Cchange of chart speed 63channel na
Page 13
112 Instrument description2.1 Display and controls Fault signal LEDThis lights up as soon as the recording is interrupted by the “endof chart paper”,
Page 14
13 Index110event traces 30, 68external report 68external scaling 67external speed 26, 67external stop 67external text 36, 66extra codes 91Ffanfold cha
Page 15
11113 IndexMmasking 106mathematical module 66measurement input 57measurement range 52, 74–75Nnote signs 9Oopen-collector 25, 63operating examples 53–5
Page 16
13 Index112service print 50, 55setup program 95S-level 18, 55software version 50, 55speed in limit operation 63start text 47, 65start-up 7static displ
Page 20
JUMO GmbH & Co. KGStreet address:Moritz-Juchheim-Straße 136039 Fulda, GermanyDelivery address:Mackenrodtstraße 1436039 Fulda, GermanyPostal addres
Page 21
2 Instrument description122.2 Basics of operationIn order to keep the operating and programming of the printing recorder clearand simple, the individu
Page 22
132 Instrument descriptionKeyfunctions1. Press the F key for at least 4 sec in the standard version: print out the scaling of all the active chann
Page 24
152 Instrument descriptionValue/textentryFive keys are used to enter values:h select the position to be altered, using the l and r keysh increment and
Page 25
2 Instrument description16Key inhibit If the printing recorder is fitted with the extra code “logic inputs”, then it ispossible when a selected logic
Page 26
172 Instrument descriptionBasic status After the supply voltage has been applied, the printing recorder will be initial-ised and is then in the basic
Page 27
2 Instrument description18Example of the basic status for a 6-channel recorderOperating level(S-level) The operating level can be accessed from the ba
Page 28
192 Instrument descriptionParameterlevel (P-level)The parameter level can be accessed from the operating level with the aid ofthe h + R keys, from the
Page 29
Key functionse — Paper (chart) fast-forward,when recording is stopped(in basic status)- Abort parameterentry (Exit)- Leave the levelsS — Start/Stopof
Page 30
2 Instrument description20After a valid code number has been entered, the following parameters can bealtered in the parameter level:- language- date &
Page 31
212 Instrument descriptionConfigurationlevel 2 (C2-level)Configuration level 2 can be accessed from configuration level 1 with the aidof the h + R key
Page 32
2 Instrument description22Configurationlevel 3 (C3-level)Configuration level 3 can be accessed from configuration level 2 with the aidof the h + R key
Page 33
233 Operation and visualisationThe printing recorder has a large variety of possibilities for presenting themeasurements acquired at the signal inputs
Page 34
3 Operation and visualisation24LK function: lk8As well as producing the text print-out, the results from- limit comparators 1 to 3 can be fed to the o
Page 35
253 Operation and visualisation3.2 Open-collector outputsThe printing recorder is equipped with four open-collector outputs. The out-puts 1 to 3 have
Page 36
3 Operation and visualisation263.3 Different chart speeds (paper feed)The printing recorder is equipped with several different chart speeds, so thatth
Page 37
273 Operation and visualisation3.4 Graphic print-outThe printing recorder is fitted with a print head which always has 6 colourpens, regardless of the
Page 38
3 Operation and visualisation28Example: If three traces lie on top of one another, then the alternating print pattern en-sures that no point has a mul
Page 39
293 Operation and visualisation3.4.1 Measurement traces (signal traces)In the factory setting, all the measurement traces are printed over the full ch
Page 40
Contents1 Introduction 71.1 Preface … 71.2 Ar
Page 41
3 Operation and visualisation30These minimum and maximum values are printed when peak value recordingis activated. One advantage of the peak value rec
Page 42
313 Operation and visualisation3.5 Text printingAs well as the traces of the chart, the recorder can also print text. Text printingis used to make com
Page 43
3 Operation and visualisation32If texts with the same priority cannot be printed at once, then the order inwhich they will be printed is not determine
Page 44
333 Operation and visualisationIn the following cases, all current request for text printing will be cancelled,and any fresh ones will be ignored:- Re
Page 45
3 Operation and visualisation343.5.2 Printing modesTexts can be printed in two modes:- by interrupting the measurement trace (Outplot)- overwrite the
Page 46
353 Operation and visualisationDisadvantages:- the text printing can take a very long time- the printing of other texts is blocked- text printing is n
Page 47
3 Operation and visualisation363.5.4 Limit comparator texts, external text, binary-linked external textLimit comparatortextsLimit comparator texts can
Page 48
373 Operation and visualisationActivation is carried out by the parameter Configuration level 3 Î Text logiclinks.Colour assignmentPrint-outs of limit
Page 49
3 Operation and visualisation383.5.5 ReportThe report is used to create statistics about the measurements, referred to adefinable period of time (stat
Page 50
393 Operation and visualisationExternal report The external report is controlled by a selectable logic input. In addition to theparameter Configuratio
Page 51
Contents3.6 Colour assignment … 513.7 Relationship between measurem
Page 52
3 Operation and visualisation40General For the report:- If the printing recorder is switched off at the end of the statistical period, then the print-
Page 53 — 4 Configuration table
413 Operation and visualisation3.5.6 Switching the chart speedEvery change of chart speed is recorded by printing out a line with the time ofthe chang
Page 54
3 Operation and visualisation423.5.7 “Power On” and “Power Off” textsThe time of “Power On” and “Power Off” can be documented by using thisfeature. Bo
Page 55
433 Operation and visualisation3.5.8 ScalingThe scaling can be printed in two different ways:cyclic:for each channel, at a configurable spacing(Config
Page 56
3 Operation and visualisation44Example:- Channel 3- Presentation range: 0 — 100mm- Limit comparator thresholds at 200 and 500°CExample:- Channel 2- Pr
Page 57
453 Operation and visualisationTriggeredscaling printTo start the triggered scaling print, the F-key must be pressed for at least 4seconds.Alternative
Page 58
3 Operation and visualisation463.5.9 TimeThe print-out is performed cyclically, at a configurable spacing (Configurationlevel 2 Î Print time).Selectab
Page 59
473 Operation and visualisation3.5.10 Print out channel numbersIn order to be able to associate measurements more clearly with a channel, thechannel n
Page 60
3 Operation and visualisation483.5.12 Incrementing the two event countersThe event counter is assigned to a freely selected logic input. Every time th
Page 61
493 Operation and visualisation3.5.13 Print testThe print test can only be initiated from the keys on the printing recorder (Op-erating level Î Print
Page 62
Contents9.2 Removing and replacing the chart cassette … 869.2.1 Changing the roll chart …
Page 63
3 Operation and visualisation503.5.14 Service printThe service print can only be initiated from the keys on the printing recorder(Operating level Î Se
Page 64
513 Operation and visualisation3.6 Colour assignmentWith the aid of the setup program you can select the colours which are usedfor print-outs.Selectio
Page 65
3 Operation and visualisation523.7 Relationship between measurement range and scalingThe printing recorder offers the facility to differentiate betwee
Page 66
534 Configuration table4.1 Operating examplesExample 1 The date, time and weekday are to be programmed.lKey Display Description5 AMB. TEMP. +35.08°C
Page 67
4 Configuration table54Example 2 Starting from example 1, the instrument designation is to be changed.lKey Display DescriptionS-LEVELh + R Start code
Page 68
554 Configuration table4.2 Table of the configuration parametersAll the parameters for the instrument are presented in the following table. Theparamet
Page 69 — 5.1 Instrument description
4 Configuration table564.2.2 Parameter level (P-Level) Parameter Value/selection DescriptionLanguage Parameter level➔ LanguageLanguage: ENGLISHGERMANF
Page 70 — 5.2 Order details
574 Configuration table4.2.3 Configuration level 1 (C1-level)Parameter Value/selection DescriptionPlot status Configuration level 1➔ Plot statusX Plot
Page 71 — 6 Installation
4 Configuration table58Range start: -9999 to +9999 Enter start ofmeasurement range1Range end: -9999 to +9999Meas. span ≥ 100°Cfor Type S, R, B ≥ 500°C
Page 72
594 Configuration tableEnd res. Re: 0 ≤ Re ≤ 4000ΩRa + Rs + Re ≤ 4000ΩMeas. span ≥ 6ΩEnter end resistanceFilter: 0.0 — 50.0sec Enter filter constantCo
Page 74
4 Configuration table60Range end: -9999 to +9999-20mA < rge. end ≤ 20mAMeas. span ≥ 0.5mAEnter end of measurementrange1Temperature:(dimension)°C, °
Page 75
614 Configuration tableLimit comparator Configuration level 1➔ Limit comparatorX Limit comparator 1 — 8 Select limit comparatorLimit value: -9999 to +
Page 76
4 Configuration table62Zoom Configuration level 1➔ ZoomX Zoom 1 — 3 or 1 — 6 Select reference channelLow: 0 — 90 Enter measurement value for start (in
Page 77
634 Configuration table4.2.4 Configuration level 2 (C2-level)Parameter Value/selection DescriptionUnit name Configuration level 2➔ Unit nameText: 16 c
Page 78
4 Configuration table64Print the time Configuration level 2➔ Print timeSpacing: OFF, 2, 4, 6cmDetermine the regular in-terval at which the time should
Page 79 — (when using transducers
654 Configuration tableStart text Configuration level 2➔ Start textStatus: OFF, ON Select the status for the print-out of the start text(if OFF: text
Page 80
4 Configuration table664.2.5 Configuration level 3 (C3-level)Parameter Value/selection DescriptionRelay output Configuration level 3➔ Relay outputX Re
Page 81
674 Configuration tableText logic links 00 — 01 (Log. input 1)00 — 03 (Log. input 1-2)00 — 07 (Log. input 1-3)00 — 15 (Log. input 1-4)Select binary co
Page 82
4 Configuration table68External report Configuration level 3➔ External reportX External reportContact:1-2OFF, Log. input 1,Log. input 2, Log. input 3,
Page 83 — 8 Starting up
695 Identifying the instrument version5.1 Instrument descriptionThe printing recorder is equipped with 3 or (optionally) 6 signal inputs, whichare ele
Page 84
71 Introduction1.1 PrefacePlease read this Operating Manual before commissioning the instrument.Keep the operating manual in a place which is accessib
Page 85 — 9 Consumables
5 Identifying the instrument version705.2 Order detailsProgrammingaccessoriesStandardaccessories- 1 Operating Manual B 70.6030.0-2 fixing brackets- ca
Page 86
716 Installation6.1 Site and climatic conditionsThe installation site should be as free as possible from vibration. Stray electro-magnetic fields, for
Page 87
6 Installation72Mounting h Insert the recorder from the front into the panel cut-out.h From the back of the panel, hook the two mounting brackets into
Page 88
737 Electrical connection7.1 Installation notesk The rules of VDE 0100 “Regulations for the installation of high-currentequipment with rated voltages
Page 89
7 Electrical connection747.2 Technical dataThermocouple inputResistancethermometerinputMeasurement range Linearisation accuracy1Fe-Con LFe-Con J EN
Page 90
757 Electrical connectionInput fromresistancetransmitter orpotentiometerDC voltage or current inputTransducer short-circuit/break Range start/end fre
Page 91
7 Electrical connection76OutputsPrinting systemElectrical dataVoltage above ± 1V not recognised not recognisedCurrent not recognised not recognised1.
Page 92 — “voltage output”
777 Electrical connectionHousingApprovals/marks of conformityPower consumption max. 35VAData buffering Through a lithium battery in RAM > 4 years,
Page 93 — Î Status = ON)
7 Electrical connection787.3 Connection diagramRear view of3/6-channel versionTerminal assignment3/6-channel versionTerminal symbolSupply as on label
Page 94 — Connections
797 Electrical connectionAnalogue inputs Inputs123456fieldResistancethermometer in 4-wire circuitResistance transmitterwith 3-wire connectionA = start
Page 95 — 10.4 Setup program
1 Introduction81.2 Arrangement of the documentationThe documentation for this instrument consists of the following parts:Operating Manual B 70.6030.0T
Page 96
7 Electrical connection80External relaymodule ER8Communicationwith externalrelay moduleFieldVoltage sourcefor external2-wiretransmitter24V / 45mA± 5%7
Page 99
838 Starting up8.1 Opening and closing the doorTurn the knob to open or close the door, .8.2 Marking the channel labelAfter the door has been opened,
Page 100 — 11 Fault-finding
8 Starting up848.3 Fitting the print headh Open the doorh Stop recording (press the S key)h Swing the display radially upwardsh Push the print head in
Page 101 — 12 Appendix
859 Consumables9.1 ConsumablesPrint head3 colours for 3-channel recorderPacking unit: 2 piecesPart No.: 003552446 colours for 6-channel recorderPackin
Page 102
9 Consumables869.2 Removing and replacing the chart cassette
Page 103
879 Consumables- When inserting the chart cassette, take care that it is centered on the tear-off edge and – guiding it with the thumb and index finge
Page 104
9 Consumables889.2.1 Changing the roll chart15263748
Page 105
899 Consumables9.2.2 Changing the fanfold chart142535 cm10 cm15 cm****** ***** ***** ****1 mENDEENDFIN
Page 106
91 Introduction1.3 Typographical conventions1.3.1 Warning signsThe signs for Danger and Warning are used in this manual under thefollowing conditions:
Page 108
9110 Extra codes and accessories10.1 Converting the chart cassette1324
Page 109
10 Extra codes and accessories9210.2 “8 logic inputs”, “interface for ER8”,“voltage output”The Extra Code provides 8 logic inputs, the serial interfac
Page 110
9310 Extra codes and accessories10.3 External relay module ER8The external relay module ER8 adds 8 switching outputs to the recorder.The sequence of t
Page 111
10 Extra codes and accessories94Connectionsto ER8ER 8ErrorPower(L+) (L-)L1 N97 98 99(+)TxDRxD RxDTxD GND(-)7.17.27.3
Page 112
9510 Extra codes and accessories10.4 Setup programThe setup program provides convenient configuration of the recorder, using anIBM-compatible PC.In ad
Page 113
10 Extra codes and accessories96The setup program is installed by means of an installation program for Micro-soft Windows.The operation of the setup p
Page 114
9710 Extra codes and accessories10.5 Mathematics and logic moduleIf the maths/logic module is de-activated, then the signals which are measuredat the
Page 115
10 Extra codes and accessories9810.6 Interface (RS422/RS485)This interface is used for communication with higher-level systems (e. g. bussystems). It
cf Экранный регистратор B 70.6510.0 Инструкция по эксплуатации 05.06 / 00467981
Визуализация ENTER Список событий ENTER Вывод данных измерений Задание параметров ENTER CompactFlash-карта ENTER Контраст Индикация скорости протяжки графика ▲ Режим отключения дисплея ▼ ENTER ▲ ▼ 2 Индикация событий ▲ CF-карта -> Данные конфигурации Данные конфигурации -> CFкарта Все данные
Содержание 1 Введение 7 1.1 Предисловие ……………………………………………………………………………………..7 1.2 Построение документации ………………………………………………………………..8 1.2.1 Структура руководства по эксплуатации
Содержание 3.3 Задание параметров …………………………………………………………………………. 41 3.4 Конфигурация ……………………………………………………………………………………. 44 3.5 Список событий
Содержание 5.7 Соединение между ПК и экранным регистратором ………………………….. 89 5.7.1 Помощник для настроек прибора …………………………………………………………89 5.7.2 Список устройств
Содержание 12 6 Предметный указатель 127
1 1.1 Введение Предисловие Прочтите настоящее руководство перед тем, как начинать работу с прибором. Храните данное руководство по эксплуатации в месте, всегда доступном для всех пользователей. Вы можете оказать нам помощь в улучшении данного руководства. Мы будем благодарны за Ваши замечания. Все
1 Введение 1.2 Построение документации Документация на настоящий прибор состоит из следующих частей: Руководство по эксплуатации B 70.6510.0 Данное руководство входит в объем поставки. Оно адресовано производителям установок и пользователям с необходимым специальным образованием. Помимо монтажа и
1 1.3 Введение Типографские соглашения 1.3.1 Предупреждающие знаки Знаки Осторожно и Внимание используются в данной инструкции следующим образом: Осторожно Этот знак используется в случаях, когда неточное исполнение или неисполнение указаний может приводить к телесным повреждениям. Внимание Этот
1 Введение 1.3.3 Графические обозначения Клавиши ▲ + ENTER Для представления клавиши используется рамка. Могут применяться символические или текстовые обозначения. При описании клавиши с функцией, зависящей от контекста, используется тот текст, который соответствует функции, активной в данный
2 2.1 Описание прибора Органы управления и индикации Цветной дисплей 320 x 240 пикселей, 27 цветов Программируемые клавиши Функция, зависящая от контекста, обозначается текстом или символами Светодиодный индикатор состояния (красный) Светится постоянно при активном сигнале тревоги Светодиодный
2 Описание прибора Открывание и закрывание дверцы прибора Заглавная строка Строка состояния Для открывания и закрывания дверцы прибора поверните рукоятку 2.2 Принцип управления и графические элементы Клавиши Управление экранным регистратором осуществляется при помощи восьми клавиш. Три из этих
2 Строка состояния Описание прибора В верхней части экрана отображается строка состояния. Она содержит сведения о важных операциях или режимах. Строка состояния отображается всегда, независимо от того, выполняется управление, задание параметров или конфигурирование. Сигнал тревоги Если был выдан
2 Описание прибора Строка каналов (Представление канала) В строке каналов выводятся измеренные значения активных каналов и их единицы измерения в виде: — измеренного значения — шкалы градаций или — столбиковой диаграммы В качестве альтернативы, можно полностью отключить заглавную строку (строку
2 2.4 Описание прибора Цифровые сигналы (линии событий) Виды сигналов В шести двоичных линиях (линиях событий) можно выводить, помимо данных с четырех двоичных входов (типовое дополнение), также двоичные сигналы, выдаваемые самим прибором. Сигнал Двоичный вход 1 … 4 Описание Четыре аппаратных
2 Описание прибора Представление Графическое используется для вывода графика на экран: Представление Выходы в виде символа Представление в виде выключателя Вкл / Выкл: в виде графика Представление временного хода: Двоичные сигналы могут использоваться для управления тремя реле (типовое дополнение).
2 Описание прибора Счетчики Входы счетчиков Все двоичные сигналы могут использоваться в качестве входных сигналов для счетчиков. Ö Глава 2.4 «Двоичные сигналы (линии событий)». Например: — двоичные входы — логические каналы — сигналы тревоги — сигналы нехватки памяти — флаг Modbus (сигнал через
2 Описание прибора Счетчики времени работы Счетчик времени работы считает, сколь долго выбранный двоичный вход или один из двоичных сигналов находится в состоянии «замкнут» («установлен»). Время можно выводить в с, мин, ч и днях. 2.5.1 Время накопления состояний счетчиков Для всех счетчиков /
2 Внешний сброс Вы можете сконфигурировать для всех 6 счетчиков / интеграторов общий управляющий сигнал, который будет вызывать их сброс на 0, не вызывая записи их значений. Период суммирования для счетчиков / интеграторов начинается с этого момента заново. Это позволяет, например, после пробного
2 Описание прибора 2.5.4 При переходе на зимнее время Если задан временной период для счетчиков или интеграторов менее 1 часа, и на него попадает переход с летнего на зимнее время, то в программе обработки данных (PCA3000) время окончания периода принудительно устанавливается равным времени начала
2 Описание прибора В качестве переменных для формул в Вашем распоряжении имеются: — аналоговые входы (AE1 … AE6) — математические каналы (MAT1 … MAT6) — каналы счетчиков / интеграторов (ZI1 … ZI6) — двоичные входы (BE1 … BE4) — сигналы тревоги — неполадки — флаг Modbus (сигнал через
2 Описание прибора Логический модуль Количество логических каналов также ограничено величиной 6. Вычисленные двоичные (булевы) величины, как и прочие двоичные сигналы, могут применяться для различных функций: вывод в линиях событий, управляющий сигнал для выключения дисплея, синхронизация времени,
2 2.7 Описание прибора Режимы работы 3 Режима работы Прибор обладает 3 режимами работы: — Нормальный режим — Временной режим — Режим событий Для каждого из трех режимов можно, помимо прочего, задавать следующие настройки: — Записываемая величина — Цикл записи Записываемая величина Записываемая
2 Описание прибора 2.8 Сохранение данных Встроенная система управления данными в течение жизненного цикла позволяет пользователю сохранять все данные о процессах в контролируемой установке в одном архивном файле на своем ПК или сервере. Данные измерени (напр, темпераура, °С Система управления
2 Описание прибора Принцип работы A/D 2 A/D 1 4k B CPU Рабочее ЗУ B 4k 4kB 4kB 4kB 350.000 Данных измерений внешняя CompactFlashкарта 64…256 МБ Аналоговые входы Измеряемые величины с аналоговых входов регистрируются непрерывно с циклом 250 мс и сохраняются в рабочем ЗУ. Производится проверка
2 Описание прибора Продолжительность записи Продолжительность записи зависит от многих факторов. — количество аналоговых каналов и линий событий, которые следует записывать — цикл записи — количество событий в списке событий Продолжительность записи во внутреннее ЗУ (без CF-карты) Число каналов
2 2.9 Описание прибора Считывание данных Помимо автоматического считывания на внешнюю CF-карту, имеется возможность считывать данные через интерфейс (RS232, RS485, Setup, Ethernet). Оба способа (карта / интерфейс) могут работать параллельно. По этой причине имеется также два «двоичных сигнала»,
2 28 Описание прибора
3 Управление и визуализация После включения питания экранного регистратора на его экране сначала появляется стартовый (фирменный) логотип. При этом экранный регистратор инициализируется данными последней конфигурации. После этапа инициализации на экране отображается график измеряемых величин
3 Управление и визуализация 3.1 Главное меню Главное меню является центральным пунктом, из которого можно выходить на различные уровни прибора. Доступны следующие уровни: Ö Глава 3.2 «Визуализация» Ö Глава 3.3 «Задание параметров» Ö Глава 3.4 «Конфигурация» Ö Глава 3.5 «Список событий» Ö Глава 3.6
3 3.2 Управление и визуализация Визуализация Как уже упоминалось в Главе 2.2 «Принцип управления и графические элементы», на нижнем крае экрана находятся «программируемые клавиши». В зависимости от контекста меню, они меняют свои функции, которые отображаются в виде символов или надписей. Включить
3 Управление и визуализация 3.2.1 График с цифровым выводом (измеренные значения мелкие) В режим графика можно войти из главного меню, вызвав меню «Визуализация» или нажав клавишу EXIT . — — текущие данные с аналоговых входов, включая единицы измерения измеренное значение на красном фоне Ö
3 Управление и визуализация 3.2.2 График со шкалой Начало шкалы выбранного канала. Нижняя допустимая граница выбранного канала (не отображается, если отключены сигналы тревоги) текущее значение Символическое имя канала Верхняя граница (не отображается, если отключены сигналы тревоги) Конец шкалы
3 Управление и визуализация 3.2.4 Цифровой вывод крупный (измеряемые значения крупные) Регистратор 1 10 мин/р. НОВАЯ КОНФИГУРАЦИЯ Этот режим индикации включает только цифровой вывод. Если активны более 6 сигналов (например, 6 аналоговых входов и 3 матема. С ее тических канала), то включается
3 Управление и визуализация 3.2.5 Вывод кривых (заглавная строка отключена) Регистратор 1 Канал 1 Сигнал Max 2 мин/р. ВЫКЛ Этот режим индикации включает только вывод кривых. 35
3 Управление и визуализация 3.2.6 Обработка сохраненных данных измерений История Режим пролистывания При обработке меняется функция программируемых клавиш, кроме этого выводится текущий масштаб изображения и положение курсора (дата и время суток). Текущий масштаб изображения (увеличение) Курсор
3 Управление и визуализация Обратное пролистывание данных во внутреннем ЗУ возможно не далее последнего перехода с летнего времени на зимнее. Масштаб Если необходимо изменить масштаб или осуществить поиск данных за определенный период времени, необходимо переключить функцию программируемых клавиш
3 Управление и визуализация Перемещение курсора Для перемещения курсора на определенный момент времени при помощи клавиши открывается следующий диалог: Положение курсора Дата Время После ввода даты и времени и нажатия клавиши навливается на выбранный момент времени. курсор уста- Если для выбранного
3 Управление и визуализация 3.2.7 Счетчики / интеграторы / счетчики времени работы Вывод состояний счетчиков поставляется в виде типового дополнения. Если это дополнение установлено, то после нажатия этой программируемой клавиши появляется следующий экран, на котором отображаются текущие состояния
3 Управление и визуализация Расширенный режим индикации Регистратор 1 Насос 2 Насос 1 Сток Приток 1 мин/р. Свежая вода Технич. вода Канал 4 Канал 3 3 м Суточный 3 м Счетчик № 2 Канал 2 Счетчик № 1 Канал 1 нормальный режим индикации текущее состояние счетчиков завершенный период накопления показать
3 3.3 Управление и визуализация Задание параметров Регистратор 1 1 мин/р. СЕТЬ ВКЛ Задание параметров Контраст Инд. скор. протяжки Гр. откл. дисплея Вид графика Сброс сч./инт. Время/растр На уровне задания параметров можно настраивать — контраст, — индикацию скорости протяжки графика, — режим
3 Управление и визуализация Режим отключения дисплея Событие, управляющее отключением = время ожидания Для обеспечения работы экрана в щадящем режиме можно задать параметр «Время ожидания» (0 …32767 мин). Если в течение указанного интервала времени не была нажата ни одна клавиша экранного
3 Сброс счетчиков / интеграторов Управление и визуализация После ввода правильного пароля, в этом меню Вы можете сбрасывать состояния счетчиков для каждого из 6 каналов на 0 или на другое заданное значение. После ввода значения (для завершения ввода нажмите клавишу ENTER ) в список событий
3 Управление и визуализация 3.4 Конфигурация При вызове уровня конфигурации сначала предлагается ввести пароль (заводская установка: 09200). 09200). Это позволяет предотвратить доступ посторонних к изменению конфигурации. После ввода пароля появляется предупреждение, которое следует подтвердить
3 Управление и визуализация Конфигурация экранного регистратора делится на следующие подуровни: Конфигурация Данные прибора Аналоговые входы Математич. каналы Счетчик/интегратор Регистрация Выходы Управл. функции Тексты Интерфейс Недокум. параметры Калибровка Ö Глава 4 «Параметры конфигурации» 3.5
3 Управление и визуализация Стандартные тексты Прибор предлагает стандартные тексты, приводимые в следующей таблице: Стандартный текст Примечание Каналx Сигнал Min ВКЛ Каналx Сигнал Min ВЫКЛ Каналx Сигнал Max ВКЛ Каналx Сигнал Max ВЫКЛ Сигнал Счет. / Инт. x ВКЛ Сигнал Счет. / Инт. x ВЫКЛ Двоич.
3 Главное меню Î Список событий Управление и визуализация Список событий можно вызвать через главное меню: Регистратор 1 10 мин/р. СЕТЬ ВКЛ Сведения о приборе Менеджер диска Список событий Конфигурация Задание параметров Визуализация На пользовательском уровне выберите Список событий Подтвердите
3 Управление и визуализация 3.6 CompactFlash-карта Автоматическое сохранение данных измерений Данные, записанные во внутреннем ЗУ (FLASH) экранного регистратора, автоматически сохраняются через регулярные интервалы на CompactFlashкарте1. Программа обработки данных на ПК (Ö Глава 7 «Программы для
3 CompactFlashкарта Управление и визуализация Еще не сохраненные данные измерений сохраняются на CF-карте Периоды накопления счетчиков/интеграторов завершаются и их значения сохраняются на CF-карте вместе с еще не сохраненными данными измерений. Счетчики/интеграторы сбрасываются (на 0) и
3 Управление и визуализация Сообщения о статусе 50 Сообщения о статусе менеджера CF-карты выводятся в активном окне. Возможны следующие сообщения: Сообщение о статусе Описание CF-КАРТА ОБНОВЛЕНА Непосредственно перед тем, как вынуть CF-карту из прибора, необходимо выполнить функцию CF обновить,
3 3.7 Управление и визуализация Сведения о приборе В окне Сведения о приборе выводятся различные данные о приборе. В дополнение, в этом окне также выводятся сообщения об ошибках «Батарея разряжена» и «Потеря данных». Если появилась одна из этих неполадок, символ Инфо в строке состояния начинает
3 Управление и визуализация Неполадка — Помимо прочего, в этом меню имеется номер версии (например, 208.01.01). Это номер версии программного обеспечения прибора. Он важен, так как многие функции становятся доступны лишь начиная с некоторого номера версии. — Если «Опция двоичный ввод / вывод»
3 3.8 Управление и визуализация Ввод текстов Возможности ввода Произвольно задаваемые тексты можно вводить или через программу Setup или на самом приборе. В этой главе описан ввод текстов на приборе. Таблица символов Следующее окно появляется, когда на уровне конфигурации (например, Конфигурация Î
3 Управление и визуализация 3.9 Ввод значений Ввод значений на приборе, как в приведенном примере выполнения точной калибровки, также осуществляется программируемыми клавишами. Регистратор 1 1 ч/р. СЕТЬ ВКЛ Конфигурация Калибровка Аналоговый вход 1 Статус калибровки Нач. знач. Факт. Нач. знач. ном.
3 Управление и визуализация 3.10 Код (запрос пароля) Заводские установки предусматривают защиту следующих функций паролем от несанкционированного доступа. — Меню Конфигурация — Некоторые функции меню CompactFlash-карта — меню Задание параметров Î Сброс счетчиков / интеграторов Заводская установка
3 Управление и визуализация Запрос пароля в меню Конфигурация Регистратор 1 1 мин/р. СЕТЬ ВКЛ ВНИМАНИЕ! Данные измерений во внутреннем ЗУ удаляются при изменении конфигурации. Поэтому не забудьте перед этим сохранить данные (Обновить CF-карту)! После запроса пароля в меню конфигурация появляется
4 4.1 Параметры конфигурации Пример перемещений по меню Регистратор 1 1 мин/р. СЕТЬ ВКЛ Сведения о приборе CompactFlash-карта Список событий Конфигурация Задание параметров Визуализация Конфигурация Данные прибора Аналоговые входы Математич. каналы Счетчик/интегратор Регистрация Выходы Функции
4 Параметры конфигурации 4.2 Таблица параметров конфигурации В следующей таблице приводятся все параметры прибора. Параметры описаны в той последовательности, в которой они появляются в структуре меню. В первой колонке таблицы описан «путь» по структуре меню и окон к соответствующему параметру. Во
4 Параметры конфигурации Режим индикации каналов Задание параметров Î Вид графика Î Режим индикации каналов Измер. знач. мелкие, Шкала, Столб. диаграмма, Измер. знач. крупные, Выключен Здесь задается содержимое строки каналов (заглавной строки) Вывод данных канала Задание параметров Î Вид графика Î
4 Параметры конфигурации 4.2.2 Конфигурация — Данные прибора Параметр Значения / Опции Символическое имя прибора Конфигурация Î Данные прибора Î Символическое имя прибора 16 знаков Дата Конфигурация Î Данные прибора Î Дата и время Î Дата произвольная дата Ввод текущей даты Время Конфигурация Î
4 Параметры конфигурации Язык Конфигурация Î Данные прибора Î Язык Немецкий, английский, французский, голландский, испанский, итальянский, венгерский, чешский, шведский, польский, датский, финский, португальский, русский Единица температуры Конфигурация Î Данные прибора Î Единица температуры °C, °F
4 Параметры конфигурации Заводские установки Конфигурация Î Данные прибора Î Принять завод. уст. Нет, Да Да = Принять заводскую установку (после подтверждения параметр автоматически снова установится на «Нет») Разблокирование опций Конфигурация Î Данные прибора Î Разблокирование опций
4 Параметры конфигурации Параметр Значения / Опции Холодный спай Конфигурация Î Аналоговые входы Î Аналог. вход 1…6 Î Холодный спай Внутренний Pt100, Внешний постоянный Внешняя температура холодного спая Конфигурация Î Аналоговые входы Î Аналог. вход 1…6 Î Вн. Т хол. спая -50 … +150 °C Начало
4 Параметры конфигурации 4.2.4 Конфигурация — математические каналы Параметр Значения / Опции Описание Начало шкалы Конфигурация Î Математич. каналы Î Матем. канал 1 … 6 Î Начало шкалы -99999 … 0 … +99999 Начало шкалы математического канала. Чем является математический канал, задается при помощи
4 Параметры конфигурации Входной сигнал Конфигурация Î Счетчик/интегратор Î Каналы сч./инт. Î Канал 1 … 6 Î Входной сигнал Аналог. вх. 1 … 3(6), Математический канал 1 …6 Этот параметр можно задавать только, если в меню Функция было выбрано «Интегратор». Выберите, какой вход следует интегрировать.
4 Параметры конфигурации Конфигурация Î Счетчик/интегратор Î Каналы сч./инт. Î Канал 1 … 6 Î Имя канала 12 знаков Единица Конфигурация Î Счетчик/интегратор Î Каналы сч./инт. Î Канал 1 … 6 Î Единица 5 знаков Введите здесь единицу измерения, которая вместе с введенным текстом и текущим состоянием
4 Параметры конфигурации Период Конфигурация Î Счетчик/интегратор Î Период 1 мин, 2 мин, 3 мин, 4 мин, 5 мин, 10 мин, 15 мин, 30 мин, 1 ч, 2 ч, 3 ч, 4 ч, 6 ч, 8 ч, 12 ч Можно задавать только, если хотя бы у одного счетчика/интегратора параметр Тип имеет значение «Периодический». Через указанный
4 Параметры конфигурации Управление сбросом Конфигурация Î Счетчик/интегратор Î Управление сбросом Выключена, Двоич. вход 1 … 4, Логический канал 1 … 6, Сигнал Min 1 … 6, Общий сигнал Min, Сигнал Max 1 … 6, Общий сигнал Max, Сигнал сч./инт. 1 … 6, Общ. сигнал сч./инт., Общий сигнал тревоги, CF
4 Параметры конфигурации Нижняя граница Конфигурация Î Регистрация Î Аналоговые каналы Î Аналог. канал 1 … 6 Î Выдача сигналов Î Нижняя граница -99999 … 0 … +99999 Верхняя граница Конфигурация Î Регистрация Î Аналоговые каналы Î Аналог. канал 1 … 6 Î Выдача сигналов Î Верхняя граница -99999 … 0 …
4 Параметры конфигурации Линии событий Входной сигнал Символическое имя линии Конфигурация Î Регистрация Î Линии событий Î Линии событий 1 …6 Î Входной сигнал Выключен, Выключен, Двоичн. вход. 1 … 4, логич. канал 1 … 6, Сигнал Min 1 … 6, Общий сигнал Min, Сигнал Max 1 … 6, Общий сигнал Max, Сигнал
4 Параметры конфигурации Глава 2.7 «Режимы работы» Ö Глава 2.8 «Сохранение данных» Цикл записи режим событий Конфигурация Î Регистрация Î Режим событий Î Цикл записи 1 … 5 … 32767 с Ö Время начала временной режим Конфигурация Î Регистрация Î Временной режим Î Время начала произвольное время
4 Параметры конфигурации 4.2.8 Конфигурация — Функции управления Параметр Значения / Опции Описание Пользовательские тексты Двоичный вход 1 …4 Конфигурация Î Функции управления Î Пользовательские тексты Î Двоичный вход 1…4 Стандартный текст, Текст 1 … 18, Нет текста Ö Глава 3.5 «Список событий»
4 Параметры конфигурации 4.2.10 Конфигурация — Интерфейс Параметр Значения / Опции Описание Тип интерфейса Конфигурация Î Интерфейс Î Тип интерфейса RS232, RS485 Выбор последовательного интерфейса (типовое дополнение) Протокол Конфигурация Î Интерфейс Î Протокол MODBUS, JBUS Скорость передачи
4 Параметры конфигурации 4.2.12 Конфигурация — Калибровка Параметр Значения / Опции Описание Статус калибровки Конфигурация Î Калибровка Î Аналоговый вход 1…6 Î Статус калибровки Выкл, Вкл Здесь можно активировать калибровку (корректировку) измеряемых аналоговых значений. Корректировка выполняется
5 Программа Setup Программа Setup является удобной средой для создания файлов конфигурации и позволяет конфигурировать прибор при помощи ПК. 5.1 Требования к аппаратному и программному обеспечению Для установки и использования программы Setup необходимо выполнение следующих требований к аппаратному
5 Программа Setup 5.2 Установка Загрузите Microsoft Windows Запустите программу установки Если Microsoft Windows уже загружена, то перед запуском программы установки следует закрыть все прочие программы под Windows. Вставьте CD в привод CD-ROM и закройте привод. После вставки CD программа установки
5 5.3 Программа Setup Пользовательский интерфейс программы Панель меню Панель инструментов Рабочая область Файл Передача данных Дата Дополнительно Время Окно Имя Справка Имя канала Значение Формат Нет соединения с прибором Пользователь: Специалист Статус соединения Панель меню С помощью панели меню
5 Программа Setup Перемещение панели инструментов Положение панели инструментов можно менять произвольным образом. Поместите указатель мыши между двумя группами символов. Нажмите левую кнопку мыши. Тащите панель инструментов, удерживая нажатой левую кнопку мыши, к нужной позиции. Отпустите левую
5 Файл Передача данных Дополнительно Setup Заголовок файла Уровень параметров Вывод График Уровень конфигурации Данные прибора Аналоговые входы Счетчик / интегратор Регистрация Выходы Функции управления Тексты Интерфейс Недокум. Параметры Только Setup Окно Программа Setup Справка Данные прибора
5 Программа Setup … соответствующее окно становится активным окном. Файл Передача данных Дополнительно Setup Заголовок файла Уровень параметров Вывод График Уровень конфигурации Данные прибора Аналоговые входы Счетчик / интегратор Регистрация Выходы Функции управления Тексты Интерфейс Недокум.
5 Программа Setup Аналоговые входы Î редактировать онлайн Текущая настройка аналоговых входов считывается напрямую с прибора и открывает диалог изменения свойств. Теперь можно менять конфигурацию. После изменения новая конфигурация загружается в прибор и заносится в диалоговое окно. При
5 Программа Setup 5.5 Телесервис С помощью телесервиса Вы можете запрашивать текущие данные экранного регистратора. Дополнительно можно устанавливать (активировать) флаг Modbus. Чтобы можно было использовать телесервис, должно быть установлено соединение с прибором. Ö Глава 5.7 «Соединение между ПК
5 Установка флага Modbus Программа Setup Щелкайте левой кнопкой мыши на «Правой стрелке» ( появится вкладка «Прочие двоичные сигналы». ), пока не Щелкните на вкладке «Прочие двоичные сигналы». Вкладка автоматически станет активной. Файл Передача данных Дополнительно Окно Справка Данные прибора
5 Программа Setup 5.6 Передача данных от прибора и к прибору Существуют два способа передачи данных конфигурации на экранный регистратор или из него: — Передача через CompactFlash-карту и — Передача через интерфейс. При записи новой конфигурации, данные в приборе (FLASH-ЗУ) стираются. Если
5 Экранный регистратор Программа Setup Экранный регистратор может записывать данные конфигурации на CF-карту и считывать их оттуда. Ö Глава 3.6 «CompactFlash-карта» Ошибки импорта/экспорта Если на экранном регистраторе происходит ошибка при передаче данных на CF-карту и с нее, то сообщение об
5 Программа Setup Форматирование CF-карты CF-карту следует форматировать в файловой системе FAT (не FAT32 или NTFS). Если Вы самостоятельно форматируете CF-карту, то помните, что нельзя выполнять быстрое форматирование. При нарушении этого правила невозможно гарантировать безошибочный обмен
5 Программа Setup 5.6.2 Передача через интерфейс Передача данных возможна через один из следующих интерфейсов: Экранный регистратор Интерфейс Setup Интерфейс Setup RS 232 RS 485 ПК RS 232 USB RS 232 RS 485 (Плата или преобразователь) Ethernet Ethernet Ö Setup — RS232 За сведениями о настройке
5 Программа Setup Ethernet Подключение экранного регистратора или ПК к локальной сети производится стандартными сетевыми кабелями (разъем RJ45). При прямом соединении экранного регистратора и ПК следует пользоваться так называемым crossover (перекрестным) кабелем. Получать доступ к прибору
5 Программа Setup 5.7 Соединение между ПК и экранным регистратором Для организации обмена данными между экранным регистратором и ПК необходимо, прежде всего, определить, с какими прибором и каким способом должна осуществляться коммуникация, и затем установить соединение с прибором. Соединение с
5 Программа Setup Выберите версию прибора. Введите при необходимости дополнительное описание. Активируйте при необходимости одну из опций. Нажмите на кнопку Дальше >. Помощник для настроек соединения Интерфейс ПК: Последовательный интерфейс < Назад Дальше > Отмена Выберите интерфейс, через который
5 TCP/IP порт Аналоговый модем / ISDN Программа Setup Необходимо выбрать следующие параметры: IP-адрес/ имя хоста xxx.xxx.xxx.xxx (Напр. 192.168.0.10) Номер порта, имя порта 502 Протокол передачи данных Modbus-TCP/IP, протокол Modbus Пароль на передачу данных 0 Задайте IP-адрес вашего прибора. Если
5 Программа Setup Последовательный Необходимо выбрать следующие параметры: интерфейс Подсоединен к COM1, COM2 Интерфейс ПК, к которому порту подсоединен экранный регистратор. Скорость передачи 9600, 19200, 38400 Скорость передачи должна быть той же, что и заданная в приборе. 9600 следует задавать,
5 Программа Setup Все заданные приборы отображаются в одном списке устройств. Там находится также панель управления параметрами интерфейса; в списке устройств можно определять новые, дополнительные устройства. Установить соединение с выбранным прибором Удалить прибор(ы) из списка Редактирование
5 Программа Setup 5.8 Функции меню 5.8.1 Файл Новый Открывает новую конфигурацию в рабочей области. Для значений параметров используются заводские установки. Отрыть Отрывает существующий файл конфигурацию и выводит его содержимое в рабочей области. Сохранить Сохраняет конфигурацию, выведенную в
5 Программа Setup 5.8.2 Правка Отменить … Отменяет предыдущее действие. В меню рядом с пунктом Отменить отображается действие, которое будет отменено. Вернуть … Функцию Вернуть можно использовать только, если была вызвана функция Отменить. Эта функция снова выполняет то действие, которое было
5 Программа Setup Сведения о конфигурации Эта функция соответствует двойному щелчку левой кнопки мыши на одной из следующих функций в диалоговом окне. Заголовок файла Текст файла 5.8.3 Передача данных Установить соединение Эта функция устанавливает соединение с прибором. Установленное соединение
5 Разблокирование типовых дополнений Программа Setup Эта функция предназначена для подключения расширений к экранному регистратору (например, разблокировка типового дополнения «Интеграторы и счетчики, а также Математический и логический модуль»). После запуска этой функции необходимо при помощи
5 Программа Setup Дата и время При помощи этой функции можно синхронизовать дату и время ПК и прибора. Дата / время Установка в приборе Дата / время: Считывать непрерывно Новая установка Использовать дату / время ПК Дата / время: Установить Закрыть Завершает функцию. Установить дату и время
5 Обновить регистрацию / Изменить пароль Программа Setup При помощи функции Обновить регистрацию / Изменить пароль можно — активировать запрос имени пользователя и пароля при запуске программы и — изменить текущий пароль. Функция влияет только на саму программу Setup, но не на экранный регистратор.
5 Программа Setup Задайте пароль; при этом поле «Старый пароль» оставьте пустым. Изменение пароля Имя пользователя: Специалист Старый пароль: Новый пароль: Подтвердите новый пароль: OK Отмена После окончания ввода и нажатия на кнопку новый пароль будет активирован. Теперь при запуске программы
5 Программа Setup 5.8.5 Окна При перемещении диалогового окна действуют стандартные правила Windows. Увеличить и свернуть Уменьшить и развернуть Закрыть Двойной щелчок левой кнопкой мыши разворачивает окно. Каскадом Если одновременно открыто несколько диалоговых окон, эта функция располагает их с
5 Программа Setup 5.8.6 О программе Сведения о программе Setup Здесь можно узнать номер версии программы Setup. Подготовьте заранее номер версии, если Вы собираетесь связаться с горячей линией сервиса. Документация программы Эта функция открывает имеющуюся документацию о приборе и программном
5 5.9 Программа Setup Математика / Логика Математический и логический модуль доступен в качестве типового дополнения. Его следует заказывать вместе с прибором или разблокировать при помощи функции Дополнительно Î Разблокирование типовых дополнений (страница 96). Математический и логический модуль
5 Программа Setup Выбор функций ) Здесь производится выбор функции. Все другие поля можно редактировать в зависимости от функции. Математика / логика Математика Логика Скользящее временное среднее: Функция: Нет функции Переменная a: Начало шкалы: Переменная b: Конец шкалы: Формула: Редактор формул
5 Программа Setup Пример: формула Функция: Влажность(a,b) Переменная a: Переменная b: Формула: Формулу можно вводить напрямую через клавиатуру ПК или вызывая функцию Редактор формул . После вызова функции появляется следующий диалог: Редактор формул Доступные переменные: AE1 AE2 AE3 AE4 AES AE6
5 Программа Setup Обзор операторов Приоритеты операторов Оператор Объяснение Пример + Сумма AE1 + AE2 — Разность AE1 — AE2 * Произведение AE1 * AE2 / Частное AE1 / AE2 ( открывающая скобка ( ) закрывающая скобка ) SQRT() корень SQRT (AE1) MIN() минимальное значение MIN (AE1, AE2) MAX() максимальное
5 Программа Setup 5.10 Таблица символов 032 033 034 035 036 037 038 039 040 041 042 ! » # $ % & ’ ( ) * 080 081 082 083 084 085 086 087 088 089 090 P Q R S T U V W X Y Z 0161 0162 0163 0164 0165 0166 0167 0168 0169 0170 0171 ¡ ¢ £ ¤ ¥ ¦ § ¨ © ª « 0209 0210 0211 0212 0213 0214 0215 0216 0217 0218
5 Программа Setup Ввод специальных символов (Специальные) символы, которые нельзя ввести непосредственно с клавиатуры ПК, вводятся при помощи клавиши Alt и цифрового кода, приведенного в таблице. Пример Необходимо ввести специальный символ ©: Подведите курсор с помощью мыши или клавиш перемещения
6 6.1 Права доступа Права доступа к функциям программы Setup В зависимости от установки и регистрации различные пользователи обладают различными правами доступа к функциям программы Setup. Различия сведены в следующей таблице. Права Демоверсия Техническое Специалист обслуживание Писать тексты
6 110 Права доступа
7 7.1 Программы для ПК Программа обработки данных (PCA3000) PCA3000 детально описана в руководстве пользователя B 70.9701.0. PCA3000 является профессиональным программным обеспечением для анализа архивированных данных измерений, записанных при помощи прибора. Архив Правка Масштаб Вид Дополнительно
7 Программы для ПК 7.2 Программа для коммуникации PCC PCC детально описана в руководстве пользователя B 70.9702.0. Файл Правка Передача данных Список устройств Тип уст-ва: Регулятор Тип уст-ва: Регистратор Регистратор 1 Соединение Время Архив События Ошибки Автоматика Дополнительно Вид Справка
8 8.1 Идентификация исполнения прибора Элементы обозначения типа Экранный регистратор экономического класса с носителем данных «CompactFlash-карта» и системой управления данными в течение жизненного цикла. (1) Базовая модель 706510/14 Экранный регистратор с 3 аналоговыми входами 706510/24 Экранный
8 Идентификация исполнения прибора 8.2 Серийные принадлежности 8.3 114 — 1 руководство по эксплуатации B 70.6510.0 — 2 крепежных элемента или 4 крепежных элемента при наличии типового дополнения 266 — 1 уплотнение для распределительного щита при наличии типового дополнения 266 — 4 прижимных
9 9.1 Монтаж Место монтажа и климатические условия Место монтажа не должно подвергаться вибрациям. Следует избегать мест, подверженных действию внешних электромагнитных полей, создаваемых, например, двигателями, трансформаторами и т.д. Температура окружающей среды может находиться в пределах 0 …
9 Монтаж Монтаж Вставьте экранный регистратор в выемку распределительного щита спереди. Проденьте два крепежных элемента с задней стороны распределительного щита в боковые выемки корпуса. Плоские бока крепежных элементов должны прилегать к корпусу. Выемка для крепежного элемента Уприте крепежные
9 Типовое дополнение 266 (IP65) Монтаж При монтаже экранного регистратора с типовым дополнение 266 (IP65) необходимо выполнять следующие указания: — Уплотнение распределительного щита следует установить перед монтажом прибора. Внимание! Убедитесь, что уплотнение находится в правильном положении.
9 118 Монтаж
10 Электрическое подключение 10.1 Указания по монтажу При выборе материала проводников, при монтаже и при электрическом подключении прибора необходимо выполнять директиву VDE 0100 «Предписания по монтажу сильноточных установок с номинальным напряжением ниже 1000 В» или
10 Электрическое подключение Электрическое подключение может выполняться только квалифицированным персоналом. Вид сзади (L-) (L+) 30. PE N L1 31. 32. 1 1 20. 33. 1 1 Выемки для кабельных бандажей с крепежной ножкой для уменьшения растягивающего усилия кабелей 21. 1 1 1 4. 1 5. 1 1. 6. 1 2.
10 Электрическое подключение Термометр сопротивления в двухпроводной схеме 1-й … 6-й Термометр сопротивления в трехпроводной схеме 1-й … 6-й Термометр сопротивления в четырехпроводной схеме 1-й … 6-й Вход по напряжению ≤ 210 мВ 1-й … 6-й Вход по напряжению > 210 мВ 1-й … 6-й Вход по току
10 Электрическое подключение Двоичные входы (типовое дополнение) 33. Электрическое питание 24 В/50 мА 6 +24 В 5 GND Двоичные входы управляемые напряжением 4 Двоичный вход 1 3 Двоичный вход 2 2 Двоичный вход 3 1 Двоичный вход 4 Пример: Двоичный вход 4, управляемый встроенным питанием LOW = -3 … +5
Настоящий технический отчет можно воспроизводить только в его полной форме. Применение в рекламных целях допускается только с письменного разрешения. Отчет содержит результат разовой проверки изделия, представленного для прохождения контроля, и не является общим положительным заключение о
124 3.1 Контроль качества при проверке 2 Объем проверки Общие критерии для деятельност и отделов контроля EN 4500 1 (05 .90 ) Руководство по эксплуатации В95 .5010.0.1 Руководство по эксплуатации B95 .5010.2.2 Общая блок -схема обработ ки данны х и обзоры функ ций Раз личные планы и протоко лы
Параметры протокола ил и дата 5- значный па роль за щища ет были изм енены посторонними . доступ к меню конфигурации. При боры поста вляются с акт ивиров анн ой защитой доступа. Все из менения конфигурации прото колируются. Защи та конфигурации прибора от случа йных изменен ий 4 11 февраля 2000
126 11 февраля 2000 Страница 7 из 7 80339 München Телефон: +49(089)5791-1797; Факс: -1396 Заказ № 10053052 Отчет № MF58870,Версия 1.0 Исполнитель: Райнер Хайльман Ridlerstraße 65 Автоматизация, программное обеспечение и электроника — IQSE TÜV PRODUCT SERVICE GMBH Райне р Хайльман По поручению
12 Stichwortverzeichnis А Адрес прибора 73 Активный режим 23 Активация запроса на ввод пароля 99 Аналоговые входы 62–63, 68–69 Б Батарея разряжена 51–52 Безопасность обработки данных 123 Блокировка клавиатуры 72 В Ввод в эксплуатацию 7 Ввод знаков 53 Ввод текстов 53 Верхняя граница 69 Веса
12 Stichwortverzeichnis Г Гистерезис 69 Главное меню 11, 30 Графические обозначения 10 Д Данные Считывание через параллельный интерфейс 27 Обработка 27 Дата 60 Дата и время 98 Датчик 62 День недели (счетчик/интегратор) 67 Диапазон измерений 63 Дисплей 11 Дополнительный текст 46 Допустимая граница
12 Stichwortverzeichnis И Изменение пароля 100 Изменить пароль 99 Измерение влажности 104 Импорт данных с CF-карты 96 Имя канала (счетчик/интегратор) 65–66 Индикация скорости протяжки графика 58 Интегратор 17, 64 История 36 К Калибровка 74 Канал (счетчик/интегратор) 64 Каскадом (расположение окон)
12 Stichwortverzeichnis Л Летнее время 60 Линеаризация 62 Линии событий 15 Логический модуль 22, 103 Приоритеты операторов 106 М Масштаб 37 Масштаб времени (Счетчик/интегратор) 65 Математический модуль 20, 103 Приоритеты операторов 106 Обзор операторов 106 Место монтажа 115 Монтаж 115 Монтаж на
12 Stichwortverzeichnis Органы управления и индикации 11 Отрыть 94 Отсылка (узлов и деталей производителю) 7 Ошибки импорта/экспорта 85 П Папка установки программы 102 Пароль 43–44, 48, 55, 57, 61 Пароль доступа к функциям CF-карты 61 Пароль RS232/RS485 61 Передача данных к прибору 96 Передача
12 Stichwortverzeichnis Программируемая клавиша 11–12 Программное обеспечение прибора 52 Проекции 115 Протокол 73 Р Разблокирование опций Код оборудования 62 Ключ разблокирования 62 Разблокирование опций 62 Разблокирование опций программы 96 Разблокирование типовых дополнений 97 Разорвать
12 Stichwortverzeichnis Строка каналов 14, 59, 68 Строка состояния 13 Схема соединений 120 Статус соединения 78, 101 Счетчик 17, 64 Счетчик времени работы 18 Считывание ЗУ 61 Т Таблица символов 53 Текст сигнала (счетчик/интегратор) 66 Текст сигнала Max 69 Текст сигнала Min 69 Текст счетчика
12 Stichwortverzeichnis Ц Цветной дисплей 11 Цикл записи 23, 70–71 Цифровой вывод 31, 34 Ч Частота счетчика (счетчик/интегратор) 17 Ш Шкала 33 Щ Э Экранная заставка 11, 42, 58 Экранный вывод 10 Экспорт данных на CF-карту 96 Электростатический разряд (ESD) 7 Элементы обозначения типа 113 Я Язык 61 C
12 Stichwortverzeichnis 135
JUMO GmbH & Co. KG Адрес: Moltkestraße 13 – 31 36039 Fulda, Germany Адрес доставки: Mackenrodtstraße 14 36039 Fulda, Germany Postadresse: 36035 Fulda, Germany Телефон: +49 661 6003-727 Факс: +49 661 6003-508 e-mail: mail@jumo.net Internet: www.jumo.net 136 JUMO Mess- und Regelgeräte Ges.m.b.H.
2
Визуализация
Список событий
ENTER
ENTER
Вывод данных измерений
Индикация событий
Задание параметров
CompactFlash-карта
ENTER
ENTER
Контраст
CF-карта -> Данные
конфигурации
Индикация скорости
протяжки графика
Данные конфигурации -> CF-
карта
Режим отключения дисплея
Все данные измерений -> CF,
Вид графика
CF текущее состояние, вкл.
счетчики
▲
▼
Сброс
счетчиков/интеграторов
▲
▼
Обновить данные на CF
Конфигурация
Сведения о приборе
ENTER
ENTER
Данные прибора
Номер версии
Аналоговые входы
Номер VdN
Математические каналы
Заводской №
Счетчик/интегратор
Входная плата 1
Регистрация
Входная плата 2
Выходы
Опция двоичный ввод/вывод
Функции управления
Опция Математика
Тексты
Опция Счетчик/интегратор
Интерфейс
Неполадка
Недокум. параметры
Питание Выкл
▲
▼
Калибровка
▲
▼
Питание Вкл